Creeping Time; Braking Time Learning Function; Accel/Decel Suspend - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

F347

Creeping Time

Program Torque Torque Control
Once the Creep function of
duration of activation of the Creep function.

Braking Time Learning Function

Program Torque Torque Control
This parameter is used to establish approximate settings for parameters F343,
F345, F346, and F347.
Note:
Setting this parameter should be done using a light load only.
Set this parameter to Brake Signal Learning. Provide a Run command. The
aforementioned parameters will receive approximate values. Application-
specific adjustments may be required when finished.
Settings:
0 — Disabled
1 — Enabled

Accel/Decel Suspend

Program Fundamental Accel/Decel 1 Settings
To maintain a constant speed setting while running, this parameter may be used
to suspend speed changes for a user-set length of time.
The Accel/Decel Suspend function is enabled by setting this parameter to
either Terminal Board Input or to
Selecting Terminal Board Input at this parameter requires that a discrete input
terminal be set to Dwell Signal (see
settings). Upon activation of the Dwell Signal terminal the output frequency
remains at the at-activation speed for the duration of the activation. When
deactivated the programmed accel or decel ramp resumes.
Selecting
F350
F353
deceleration Suspend Frequency and Suspend Time settings be completed at
F350, F351, F352, and F353. Upon reaching the frequency setting of
(Accel) or
F352
(Decel), the Accel/Decel ramp will cease and the output
frequency will hold at the threshold frequency setting for the time setting of
F351
for acceleration or
Settings:
0 — Off
1 —
F350
F353
Settings
2 — Terminal Board Input
144
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
F346
is activated, this parameter determines the
F350
– F353.
Table 5 on pg. 234
at this parameter requires that the acceleration and/or the
F353
for deceleration.
Direct Access Number — F347
Parameter Type — Numerical
Factory Default — 0.10
Changeable During Run — Yes
Minimum — 0.0
Maximum — 2.50
Units — Seconds
Direct Access Number — F348
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Direct Access Number — F349
Parameter Type — Selection List
Factory Default — Off
Changeable During Run — Yes
for a listing of available
F350
H9 ASD Installation and Operation Manual
F349

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents