F941
Input Function Target 1
Program My Function My Function Unit 5
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 1
terminal.
This setting assigns the function of the programmable Input Function Target 1
terminal to any one of the user-selectable functions listed in
Table 8 on pg.
239, or
See
F977
for more information on this parameter.
Input Function Command 1
Program My Function My Function Unit 5
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 11 on pg. 243
lists the available selections. Their use and selection
requirements are described in an example at F977.
Input Function Target 2
Program My Function My Function Unit 5
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 2
terminal.
This setting assigns the function of the programmable Input Function Target 2
terminal to any one of the user-selectable functions listed in
Table 8 on pg.
239, or
See
F977
for more information on this parameter.
Input Function Command 2
Program My Function My Function Unit 5
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 11 on pg. 243
lists the available selections. Their use and selection
requirements are described in an example at F977.
Input Function Target 3
Program My Function My Function Unit 5
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 3
terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any one of the user-selectable functions listed in
Table 8 on pg.
239, or
See
F977
for more information on this parameter.
222
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Table 10 on pg.
241.
Table 10 on pg.
241.
Table 10 on pg.
241.
Direct Access Number — F941
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Table 7 on pg.
238,
Direct Access Number — F942
Parameter Type — Selection List
Factory Default — 0 (NOP)
Direct Access Number — F943
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Table 7 on pg.
238,
Direct Access Number — F944
Parameter Type — Selection List
Factory Default — 0 (NOP)
Direct Access Number — F945
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Table 7 on pg.
238,
H9 ASD Installation and Operation Manual