Lead Length Specifications - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

Lead Length Specifications

Adhere to the NEC and any local codes during the installation of ASD/motor systems. Excessive lead
lengths may adversely effect the performance of the motor. Special cables are not required. Lead lengths
from the ASD to the motor in excess of those listed in
of the ASD.
Model
230-Volt
460-Volt
Note:
Contact the TIC Customer Support Center for application assistance when using lead
lengths in excess of those listed.
Exceeding the peak voltage rating or the allowable thermal rise time of the motor
insulation will reduce the life expectancy of the motor.
When operating in the Vector Control mode the carrier frequency should be set to
2.2 kHz or above.
20
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Table 1
lists the suggested maximum lead lengths for the listed motor voltages.
Table 1. Lead Length Recommendations.
PWM Carrier
NEMA MG1 Part 31
Frequency
Compliant Motors
All
< 5 kHz
5 kHz
Table 1
may require filters to be added to the output
NEMA MG1 Part 30
Compliant Motors
1000 feet
600 feet
300 feet
H9 ASD Installation and Operation Manual
450 feet
200 feet
100 feet

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents