Trips/Faults - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

Trips/Faults

A Trip is an H9 ASD response to a Fault (though Fault and Trip are sometimes used interchangeably).
A Trip is a safety feature that disables the ASD system in the event that a subsystem of the ASD is
malfunctioning or a parameter setting has been exceeded.
Listed in
Table 14
incurred the system displays the Fault screen. The Fault screen identifies the active Fault.
LED Screen
E
E-10
E-11
E-12
E-13
E-17
E-18
E-19
E-20
E-21
E-22
E-23
E-24
248
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
are the Faults that may result in a Trip and the possible causes. When a Trip is
Table 14. H9 ASD Fault Listing.
LCD Screen
Emergency Off
• Emergency Off command received via EOI or remotely.
Sink/Source Setting
• Improperly positioned Sink/Source jumper on the Terminal board or on an
Error
option device (see J100 at the Terminal PCB of the ASD).
• Sink/Source configuration is incorrect.
Brake Sequence
F630
Response Error
• Braking sequence discrete input and output terminals are not setup properly.
Encoder Signal-Loss
• ASD is configured to receive a signal from a shaft-mounted encoder and no
Error
signal is being received while running.
• Disconnection at the Encoder circuit.
• Motor is stopped and is generating torque via torque limit control.
• ASD is not configured properly.
Speed Error
• Result of a motor speed that is greater than the commanded speed when
using an encoder for speed control.
• Improper encoder connection or setup information.
• Defective encoder.
Key Failure
• Same key input for 20 seconds or more.
Analog (Terminal)
• V/I signal loss.
Input Loss
• Terminal Board failure.
• P24 over-current condition.
F633
CPU Communication
• CPU data Transmit/Receive error.
Error
V/f Control Error
• Torque processing error.
• Make service call.
CPU Processing Error
• Software processed incorrectly.
• Make service call.
Logic Input Voltage
• Incorrect voltage applied to the discrete input terminals.
Error
Optional Expansion
• Optional Expansion Input Terminal Board 1 is defective.
Input Terminal Board 1
Error
Optional Expansion
• Optional Expansion Input Terminal Board 2 is defective.
Input Terminal Board 2
Error
Possible Causes
is set to a non-zero value.
setting is too high.
H9 ASD Installation and Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents