Monitor Output Function Command 31; Monitor Output Function 41; Monitor Output Function Command 41 - Toshiba H9 ASD Installation And Operation Manual

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

F970

Monitor Output Function Command 31

Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function feature by allowing
the user to select the Peak, Minimum, or Normal (Avg.) value of the
parameter
F969
selection to be recorded and output as a monitored function.
See the My Function Instruction Manual (P/N E6581335) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.
Settings:
0 — Normal
1 — Peak
2 — Minimum

Monitor Output Function 41

Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function feature by
establishing the function that is to be recorded and output as the Peak,
Minimum, or Normal (Avg.) value as selected at parameter F972.
Select the Monitor Display Input Setting number from
output the corresponding function.
Use the Communication Number if operating using communications.
See the My Function Instruction Manual (P/N E6581335) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.

Monitor Output Function Command 41

Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function feature by allowing
the user to select the Peak, Minimum, or Normal (Avg.) value of the
parameter
F971
selection to be recorded and output as a monitored function.
Settings:
0 — Normal
1 — Peak
2 — Minimum
See the My Function Instruction Manual (P/N E6581335) for a complete
description of the setup requirements and operational information of the
Monitor Output Function parameter.
H9 ASD Installation and Operation Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Direct Access Number — F970
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes
Direct Access Number — F971
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Table 10 on pg. 241
to
Direct Access Number — F972
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes
F972
229