Toshiba H9 ASD Installation And Operation Manual page 187

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

F561
Preset Speed 1 Operation Mode
Program Pattern Run Operation Mode
This parameter is enabled at
direction of Preset Speed 1.
This screen is comprised of 4 fields that are labeled as follows: Direction, Acc/
Dec Group, V/f Group, and Torque Limit Group. Scroll to the field of
interest and press the scroll knob (Enter). Using the scroll knob, set the value
and press the scroll knob (Enter).
Parameters
F562
F575
Speeds 2 – 15.
When using communications write the appropriate byte to location
indicated below.
Settings:
0 — Forward Run
1 — Reverse Run
2 — Accel/Decel Switching 1
4 — Accel/Decel Switching 2
8 — V/f Switching Signal 1
16 — V/f Switching Signal 2
32 — Torque Limit Switching Signal 1
64 — Torque Limit Switching Signal 2
Writing the following data to location
Forward Run, A/D SW 2, V/f SW 3, Torque Lim SW 4.
Torque Limit
Switch 2
1
1
64
32
00=T-Lim 1
01=T-Lim 2
10=T-Lim 3
11=T-Lim 4
Preset Speed 2 Operation Mode
Program Pattern Run Operation Mode
Same as Preset Speed 1 Operation Mode (see F561).
Preset Speed 3 Operation Mode
Program Pattern Run Operation Mode
Same as Preset Speed 1 Operation Mode (see F561).
180
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
F560
and is used to set the speed, torque, and
are used to set the functions listed here for Preset
F561
via communications results in:
V/f Switch
A/D Switch
1
1
0
0
16
8
4
2
00=V/f 1
01=V/f 2
10=V/f 3
11=V/f 4
Direct Access Number — F561
Parameter Type — Selection List
Factory Default — Forward Run
Changeable During Run — No
F561
as
F/R
0
1
0=F
1=R
00=A/D 1
01=A/D 2
10=A/D 3
11=A/D 4
Direct Access Number — F562
Parameter Type — Selection List
Factory Default — Forward Run
Changeable During Run — No
Direct Access Number — F563
Parameter Type — Selection List
Factory Default — Forward Run
Changeable During Run — No
H9 ASD Installation and Operation Manual
F563

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents