Toshiba H9 ASD Installation And Operation Manual page 254

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

LED
LCD
Screen
Screen
ASD Overload
*OLI
Motor Overload
OLM
Resistor Overload
*OLR
Over-Voltage
*OP
Over-Torque
OT
Control Under-Voltage
*POFF
Reference Point
PtSt
Under-Current
UC
* Reset ignored if active.
H9 ASD Installation and Operation Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Description
Load requirement in excess of
the capability of the ASD.
Load requirement in excess of
the capability of the motor.
Excessive current at the
Dynamic Braking Resistor.
DC bus voltage exceeds
specifications.
Torque requirement is in excess
of the setting of
F616
or
F617
for a time longer than the setting
of F618.
Under-voltage condition at the 5,
15, or the 24 VDC supply.
Two speed-reference frequency
setpoint values are too close to
each other.
With the Low-Current Trip
(F610) parameter enabled, the
output current of the ASD is
below the level defined at
F611
and remains there for a time
longer than the setting of F612.
Possible Causes
• The carrier frequency is too high.
• An excessive load.
• Acceleration time is too short.
• DC damping rate is set too high.
• The motor is starting into a spinning load after a
momentary power failure.
• The ASD is improperly matched to the application.
• V/f parameter improperly set.
• Motor is locked.
• Continuous operation at low speed.
• The load is in excess of what the motor can deliver.
• Deceleration time is too short.
• DBR configuration improperly set.
• ASD attempting to start into a spinning motor after a
momentary power loss.
• Incoming commercial power is above the specified
range.
• Decel time is too short.
• Voltage spikes at the 3-phase input; install inductive
filter.
• DBR required.
• DBR resistance value is too high.
• DBR function is turned off.
• Over-Voltage Stall feature is turned off.
• System is regenerating.
• Load instability.
• Disable the Ridethrough function (F302).
• ASD is not correctly matched to the application.
F616
or
F617
setting is too low.
• Obstructed load.
• Defective Control board.
• Excessive load on power supply.
• Low input voltage.
• Two speed reference frequency setpoints are too close to
each other (increase the difference).
• Output current too low.