GRAUPNER MC-32 Manual page 269

Hide thumbs Also See for MC-32:
Table of Contents

Advertisement

Column, "Output"
The three ring limiters are pre-assigned to receiver
outputs 3/4, 9/10 and 11/12 by default, whereby the
outputs in column "X" are for the forward/reverse
function and the outputs in column "Y" are for the left/
right function. However, this preset combination of
receiver outputs can be replaced as necessary by
any other combination at any time. This is essentially
done in the same manner as described previously
under "Input", for example:
R I N G
L I M I T
4
3
4
3
4
3
10
9
3
6
7
4
X
Y
X
Y
Input
Output
Note:
Watch out for undesirable overlaps if you use
one of the outputs within a mixer.
Column, "SET"
The SET column is used to determine just which of
the ring limiters is to be "OFF" and which are to be
"ON", i. e. active. Use the selection keys on the left
or right touch pad to move the marker frame to the
desired value field in the SET column then briefly tap
the centre SET key of the right touch pad:
4
3
4
3
4
3
X
Y
Input
In the value field now displayed in inverse video,
make a choice between the two options, "ON" and
"OFF", with the  or  selection keys then con-
clude the entry with a brief tap on the centre
OFF
of the left touch pad or on the centre
right touch pad.
OFF
A tap on the  or  keys of the right touch pad
OFF
at the same time (CLEAR) will reset the active value
field back to its "OFF" default value.
SET
Column
4
3
4
3
4
3
X
Y
Input
Following a selection of one of the three lines with
the selection keys, switch to the settings page for the
selected ring limiter (1 ... 3) with a brief tap on the
centre
SET
key of the right touch pad.
R I N G
L I M I T
4
3
OFF
10
9
OFF
6
7
OFF
X
Y
Output
SET
ESC
key
SET
key of the
R I N G
L I M I T
4
3
ON
10
9
ON
6
7
ON
X
Y
Output
SET
Ring Limit 1
CH 4
CH 3
100%
100%
0%
0%
VSP OUT X VSP OUT Y
max-X
0%
If, however, the small diamond at the centre of the
circle in the figure above (which represents the cur-
rent stick position) is not visible ...
Ring Limit 1
CH 4
CH 3
100%
100%
0%
0%
VSP OUT X VSP OUT Y
max-X
0%
... then the respective ring limiter is still switched
"OFF". In this case, switch back to the previous page
with a brief tap on the centre
ESC
key of the left
touch pad then switch the respective ring limiter "ON"
as previously described.
Programming procedure
The two upper value fields – labeled at the bottom left
of the display as "max-X" or "max-Y", depending on
the position of the marker frame – are used to specify
separate settings for each of the two control func-
tions, "left/right" and "forward/reverse" within a range
of 25 ...
Program description - Ring limiter
0%
0%
269

Advertisement

Table of Contents
loading

Table of Contents