GRAUPNER MC-32 Manual page 263

Hide thumbs Also See for MC-32:
Table of Contents

Advertisement

C H A N N E L
S E Q U E N C E R
Channel
10
ACT
Channel
11
ACT
Channel
12
ACT
channel
SET
With a simultaneous tap on the  or  selection
keys of the right touch pad (CLEAR), the given chan-
nel is reset back to "INACT".
Once control channels and their activity statuses
have been set, switch to the right column then tap on
the centre
SET
key of the right touch pad to reach the
second page, the »Channel sequence« menu's cho-
reography page. Since the call-up of the second page
in this example was issued from the "Servo 12" line,
this servo remains the object of focus after the page
change.
Channel sequencer
10
11
12
0
STEP
TIME
The previous display page permitted the selection of
participating servos and their incorporation into the
sequence. This display page will now be used to es-
tablish the sequence of steps for participating servos,
beginning with initial positions yet to be defined. The
step number, from "0" to a maximum of "9", will
be shown in the column labeled "STEP" near the bot-
tom left of the display.
Step 0: Setting initial position
Keep the focus of attention on "Servo 12" or change
to any other of the three servos by using the  keys
of the left touch pad, e. g. upward to "Servo 10".
10
11
12
0
STEP
Use one of the  selection keys of the right touch
pad, as necessary, to shift the marker frame to the
right from the column "TIME" to the value field above
the column labeled "POS" then, after a tap on the
centre
SET
within a range of ±100 % until the servo is in the de-
sired initial position. For example:
10
11
12
0%
–––
0
POS
STEP
Repeat this procedure as necessary for the other two
servos.
With a simultaneous tap on the  or  selection
keys of the right touch pad (CLEAR), the given posi-
tion value will be reset back to"0 %".
Step 1: first event
Now that initial positions have been established, the
first step can be set. This is a matter of defining what
is to be done, or not done, first, following a certain
span of time.
Channel sequencer
0%
TIME
POS
key of the right touch pad, alter this value
Channell sequencer
+90%
TIME
POS
Do this by first using the  selection keys of the left
touch pad to select one of the servos. Now tap the 
key of the left touch pad. The step number, which was
previously indicated by a "0" is now replaced by a
"1" and the value "0.0s" will appear in the field above
"TIME". Use the selection keys of the right touch pad
as ne cessary to shift the marker frame to the "TIME"
column.
Channel sequencer
–––
10
11
12
1
0.0s
STEP
TIME
Now briefly tap on the centre
touch pad to set the activation time into the value
field for the "TIME" column, e. g. 1.5 s. The current
position in time is represented in the graphic by the
dotted vertical line. It will move to the right according
to the time setting and, at the same time, the course
of servo positions will be presented as dotted lines
between time-point "0" and time-point "1".
–––
Channel sequencer
10
11
12
1
1.5s
TIME
STEP
Now set the desired servo positions for the end of the
first time span (with the same procedure as already
described for "Step 0") or leave one or more of these
servos in the same position they were in for the previ-
ous step.
Program description - Channel sequencer
+90%
–––
POS
SET
key of the right
+90%
–––
POS
263

Advertisement

Table of Contents
loading

Table of Contents