GRAUPNER MC-32 Manual page 254

Hide thumbs Also See for MC-32:
Table of Contents

Advertisement

TELEMETRY
RX CURVE
V3.98
ALL–MAX
: 2000µsec
TELEMETRI RCV
ALL–MIN
: 1000µsec
SETTING & DATAVIEW
TEST
:
STOP
ALARM VOLT : 3.8V
SENSOR SELECT
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
VOICE TRIGGER
Now, with one of the selection keys of the right touch
pad, select START:
TELEMETRY
RX CURVE
V3.98
TELEMETRI RCV
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
SETTING & DATAVIEW
TEST
:
START
SENSOR SELECT
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
VOICE TRIGGER
A brief tap on the centre
SET
key of the right touch
pad will now start the test run. The input field is
shown as "normal" again:
TELEMETRY
RX CURVE
V3.98
TELEMETRI RCV
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
SETTING & DATAVIEW
TEST
: START
ALARM VOLT : 3.8V
SENSOR SELECT
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
VOICE TRIGGER
To stop the servo test, reactivate the entry field as
described above, select
STOP
and confirm this selec-
tion with the
SET
key of the right touch pad.
254 Program description - Telemetry
ALARM VOLT (receiver undervoltage warning)
The receiver voltage is monitored through ALARM
BIND. 1
VOLT. The interval can be adjusted between 3.0 and
7.5 Volt.
If the set alarm threshold is undercut, an acoustic
signal is issued (interval peep tone long/short) and
"VOLT.E" blinks in the top right of all »RX ...« dis-
plays:
TELEMETRY
RX SERVO
OUTPUT CH: 01
TELEMETRI RCV
REVERSE
SETTING & DATAVIEW
CENTER
BIND. 1
TRIM
SENSOR SELECT
TRAVEL–
RF STATUS VIEW
TRAVEL+
PERIOD
VOICE TRIGGER
The parameter "R-VOLT" is also represented inverse-
ly in the »RX DATAVIEW« display:
TELEMETRY
RX DATAVIEW
TELEMETRI RCV
S–QUA100%S–dBM–030dBM
S–STR100% R–TEM.+28°C
SETTING & DATAVIEW
L PACK TIME 00010msec
R-VOLT
SENSOR SELECT
L.R-VOLT:03.5V
BIND. 1
RF STATUS VIEW
SENSOR1 :00.0V
SENSOR2 :00.0V
VOICE TRIGGER
ALARM TEMP +/- (recommended temperature
monitoring)
These two options monitor the receiver temperature.
A lower threshold "ALARM TEMP-" (-20 ... +10 °C) and
an upper threshold "ALARM TEMP+" (50 ... 80 °C) can
be programmed.
When these specifications are exceeded or undercut,
an acoustic signal (continuous peep tone) sounds
and "TEMP.E" appears in the top right of all receiver
displays. In addition, the parameter "R-TEM" is shown
inversely on the "»RX DATAVIEW«" display page.
Make sure that your receiver remains within the per-
missible temperature range during all flight conditions
(ideally between -10 and 55 °C).
CH OUTPUT TYPE (connection type)
VOLT.E
Here you select how the receiver outputs are controlled.
BIND. 1
: OFF
: 1500µsec
: –000µsec
: 150%
: 150%
: 20msec
VOLT.E
VOLT.E
BIND. 1
:03.7V
00°C
00°C
ONCE
TELEMETRY
RX SERVO TEST
VOLT.E
TELEMETRI RCV
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
SETTING & DATAVIEW
TEST
: START
ALARM VOLT : 3.8V
SENSOR SELECT
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT
TYPE:ONCE
VOICE TRIGGER
The servo connections of the receiver are
controlled successively. This is recommended for
analog servos.
This setting automatically operates servos in a
20 ms cycle – or in a 30 ms cycle for a 12 channel
receiver (No. 33512) – , regardless of what is set
or displayed in the "PERIOD" line of the »RX
SERVO« screen!
SAME
TELEMETRY
RX SERVO TEST
VOLT.E
ALL–MAX
: 2000µsec
TELEMETRI RCV
ALL–MIN
: 1000µsec
SETTING & DATAVIEW
TEST
: START
ALARM VOLT : 3.8V
SENSOR SELECT
ALARM TEMP+: 70°C
RF STATUS VIEW
ALARM TEMP–:–10°C
CH OUT
TYPE:SAME
VOICE TRIGGER
BIND. 1
BIND. 1

Advertisement

Table of Contents
loading

Table of Contents