GRAUPNER MC-32 Manual page 253

Hide thumbs Also See for MC-32:
Table of Contents

Advertisement

an No. 7168.6A
... not only via
adapter cable
grade the receiver
but also connected to a telemetry
sensor.
However, in order for the receiver to correctly rec-
ognize the given connected device correctly, servo
connection 5 (in this case) MUST be appropriately set
for either "SERVO" or "SENSOR".
This switchover is accomplished by moving the 
with the selection key of the left or right touch pad
until the " " symbol is at the left margin of the bottom
line then tapping on the centre
SET
touch pad.
TELEMETRY
RX CURVE
V3.98
CURVE1 CH
:
02
TELEMETRI RCV
TYPE :
SETTING & DATAVIEW
CURVE2 CH
:
03
TYPE :
SENSOR SELECT
CURVE3 CH
:
04
RF STATUS VIEW
TYPE :
5CH
FUNCTION:SERVO
VOICE TRIGGER
Now use one of the  selection keys on the right
touch pad to select the alternative setting "SENSOR".
TELEMETRY
RX CURVE
V3.98
TELEMETRI RCV
CURVE1 CH
:
02
TYPE :
SETTING & DATAVIEW
CURVE2 CH
:
03
TYPE :
SENSOR SELECT
CURVE3 CH
:
04
RF STATUS VIEW
TYPE :
5CH
FUNCTION:SENSOR
VOICE TRIGGER
Another tap on the centre
SET
key of the right touch
pad will close the selection and, with appropriate
repetitive taps on the centre
ESC
key of the left touch
pad, a return to the transmitter's basic display is ac-
complished.
RX SERVO TEST
to up-
TELEMETRY
TELEMETRI RCV
SETTING & DATAVIEW
SENSOR SELECT
RF STATUS VIEW
VOICE TRIGGER
Value
key of the right
Xx.xx
BIND. 1
ALL-MAX
A
A
B
ALL-MIN
TEST
ALARM
BIND. 1
VOLT
A
A
B
ALARM
TEMP+
RX CURVE
V3.98
ALL–MAX
: 2000µsec
BIND. 1
ALL–MIN
: 1000µsec
TEST
: STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
Explanation
Possible
settings
Receiver's firmware
None
version
Servo travel on the
1500 ... 2000 µs
"+" side for all servo
outputs for the
servo test
Servo travel on the
1500 ... 1000 µs
"-" side for all servo
outputs for the
servo test
Test procedure
START / STOP
Alarm threshold
3.0 ... 7.5 V
of the receiver
factory setting:
undervoltage
3.8 V
warning
Alarm threshold for
50 ... 80 °C
excessively high
Factory setting:
temperature of the
55 °C
receiver
ALARM
Alarm threshold
TEMP–
for excessively low
temperature of the
receiver
CH
Channel sequence
OUTPUT
TYPE
ALL-MAX (servo travel on the "+" side)
In this line you set the maximum servo travel on the
plus side of the control travel for the servo test.
2000 µs corresponds to the full throw; 1500 µs corre-
sponds to the neutral position.
Make sure that the servos do not overrun mechani-
cally during the test routine.
ALL-MIN (servo travel on the "-" side)
You adjust the maximum servo travel on the minus
side of the control path for the servo test in this line.
1000 µs corresponds to the full throw; 1500 µs corre-
sponds to the neutral position.
TEST
You start and stop the servo test integrated in the
receivers in this line.
SET
A brief tap on the centre
key of the right touch
pad will open the entry field:
Program description - Telemetry
-20 ... +10 °C
Factory setting:
-10 °C
ONCE, SAME,
SUMI, SUMO and
SUMD
253