Curve MIX 9
8
10
Input
–50%
Curve
Output
0%
1
0%
off
Point
Using the selection keys on the right touch pad you
can now change the point value within a range of
±125 %, e. g.:
Curve MIX 9
8
10
Input
–50%
Curve
Output
+50%
off
Point
1
+50%
Note:
If the stick does not coincide with the exact
reference point, please note that the
percentage value on the "Output" line always
relates to the current stick position.
Continue in this way to set other reference points.
Note that the order in which you generate the (maxi-
mum) four reference points between end-points "L"
and "H" is irrelevant, since the reference points are
continuously renumbered automatically from left to
right as they are entered.
216 Program description - Free mixers
Curve MIX 9
Input
1
Curve
Output
off
Point
+
Erasing reference points
To erase one of the reference points between "L" and
"H", use the transmitter control in question to move
the vertical line onto or into the vicinity of the refer-
ence point in question. The reference point number
and associated reference point value are shown on
1
the "Point" line. If necessary, activate the Value field
by pressing the central
four-way button.
+
Now tap the two selection keys  or  on the
right touch pad at the same time (CLEAR).
The selected reference point is erased, and the num-
bering of the remaining reference points is updated
as required. Briefly tap the centre
touch pad to complete the procedure.
Note that the reference points "L" and "H" cannot be
erased.
Changing reference point values
To change reference point values, use the associ-
ated transmitter control to move the vertical line onto
the point you wish to change: "L", 1 ... 6 or "H". The
number and current curve value of this point are
displayed.
8
10
1
–50%
+50%
2
1
+50%
+
SET
button of the right-hand
ESC
key of the left
After activating the value field on the "Point" line by
SET
briefly tapping the centre
key, use the selection
keys on the right touch pad to change the current
curve value shown in the highlighted field.
The possible range is -125 % to +125 % and changes
do not affect neighboring reference points. Briefly tap
the centre
ESC
key of the left touch pad to complete
the procedure.
Note:
If the stick does not coincide with the exact
reference point, please note that the
percentage value on the "Output" line always
relates to the current stick position.
Trim point function
Alternatively, with the Point value field active (i. e.
highlighted) you can use the Select buttons  of
the left-hand four-way button to skip reference points
L, 1 ... max. 4 and H which you have already set, in
the ascending or descending direction. The selec-
tion keys on the right touch pad can then be used to
change the reference point jumped to as described
above, entirely independently of the control position.
Curve MIX 9
8
10
Trim point
Input
–50%
Curve
Output
–25%
off
Point
1
+50%
Normal
1
+

Advertisement

Table of Contents
loading

Table of Contents