Dual Rate function
If a switchover between two variants is desired, as-
sign a switch in the column labelled with the
switch symbol (as described in the section "Assigning
transmitter controls, switches and control switches"
on page 56).
Aileron
–––
100%
–––
0%
Elevator
–––
100%
–––
0%
Move desired switch
Rudder
–––
100%
–––
0%
to ON position
(ext. switch: ENTER)
DUAL
EXPO
Normal
SEL
SEL
If necessary, this may also be one of the transmitter
control switches C1 ... C8 or C1i ... C8i or one of the
logical switches L1 ... L8 or L1i ... L8i from the list of
"expanded switches".
The switch so assigned appears on the display, to-
gether with a switch icon that indicates the switch's
switching direction.
In the case of "C" or "L" switches, the stick or another
transmitter control or a certain switching logic can
itself be used as a switch. However, such a control
switch must have been appropriately defined in the
»Control switch« menu, see page 146, and a logical
switch must have been appropriately defined in the
»Logical switch« menu, see page 150.
Whichever switch has been assigned ... the respec-
tive switch will appear in the display together with a
switch symbol indicating the switch's direction if actu-
ated, e. g. in the «Normal» flight phase.
Aileron
3
100%
–––
0%
Elevator
–––
100%
–––
0%
Rudder
–––
100%
–––
0%
DUAL
EXPO
Normal
SEL
SEL
Once the value field has been activated with a brief
SET
tap on the
key of the right touch pad, use the se-
lection keys of the left or right touch pad to move into
the Dual-Rate value column labelled SEL at the bot-
tom edge of the display in order to separately change
the dual-rate values shown in inverse video for each
of the two switch positions.
Aileron
3
111%
–––
0%
Elevator
–––
100%
–––
0%
Rudder
–––
100%
–––
0%
DUAL
EXPO
Normal
SEL
SEL
Aileron
3
88%
–––
0%
Elevator
–––
100%
–––
0%
Rudder
–––
100%
–––
0%
DUAL
EXPO
Normal
SEL
SEL
At the same time, the Dual-Rate curve will be pre-
sented in the graph. A simultaneous tap on the  or
 keys of the right touch pad (CLEAR) will reset a
changed entry field value displayed in inverse video
back to "100 %".
Caution:
For safety reasons, Dual Rate value settings
should not be less than 20 %.
Some examples of Dual Rate values:
Dual Rate = 100%
Stick deflection
Exponential function
If a switchover between two variants is desired, as-
sign a switch in the column labelled with the
switch symbol (as described in the section "Assigning
transmitter controls, switches and control switches"
on page 60).
Aileron
3
100%
Elevator
–––
100%
Move desired switch
Rudder
–––
100%
to ON position
DUAL
(ext. switch: ENTER)
Normal
SEL
If necessary, this may also be one of the transmitter
control switches C1 ... C8 or C1i ... C8i or one of the
logical switches L1 ... L8 or L1i ... L8i from the list of
"expanded switches".
The switch so assigned appears on the display, to-
gether with a switch icon that indicates the switch's
switching direction.
In the case of "C" or "L" switches, the stick or another
transmitter control or a certain switching logic can
itself be used as a switch. However, such a control
switch must have been appropriately defined in the
Program description - Dual Rate / Expo | Winged models
Dual Rate = 50%
Dual Rate = 20%
Stick deflection
Stick deflection
–––
0%
–––
0%
–––
0%
EXPO
SEL