Installing Power and Ground Wiring

Installing Safety Ground and Protective Earth Wiring

1. Make sure the power cords are disconnected from the power source.
2. Connect the safety ground and protective earth wire to one of the four points shown on the
Figure 28: System Ground Connections
for system grounding).
3. AC only: Using a volt/ohm meter, measure the resistance between the ground pin on the
power plug and a ground lug in the rear of the cabinet, see
Connections
ohms, check the power cord connections.
October 2014
on page 46. The resistance can be less than 0.1 ohms; if it is greater than 0.1
Avaya Media Processing Server 1000 Hardware Installation and Maintenance