8 - 12 WiNG 5 Access Point System Reference Guide
TFTP ALG
SIP ALG
18.Refer to the
Log Dropped ICMP
Packets
Log Dropped
Malformed Packets
Enable Verbose
Logging
19.Select the
through the Firewall. The default setting is enabled. When enabled, all DHCP traffic flows are inspected.
20.Define
Flow Timeout
TCP Close Wait
TCP Established
TCP Reset
TCP Setup
Stateless TCP Flow
Stateless FIN/RESET
Flow
ICMP
UDP
Any Other Flow
Check the
Enable
default ports. This feature is enabled by default.
Check the
Enable
default ports. This feature is enabled by default.
Firewall Enhanced Logging
Use the drop-down menu to define how dropped ICMP packets are logged.
Logging can be rate limited for one log instance every 20 seconds. Options
include Rate Limited, All or None. The default setting is None.
Use the drop-down menu to define how dropped malformed packets are
logged. Logging can be rate limited for one log instance every 20 seconds.
Options include Rate Limited, All or None. The default setting is None.
Select this option to enable verbose logging for dropped packets. This
setting is disabled by default.
Enable Stateful DHCP Checks
intervals for the following flow types impacting the Firewall:
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 30 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 10,800 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 10 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 10 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 90 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 10 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 30 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 90 seconds.
Define a flow timeout value in either Seconds (1 - 32,400), Minutes
(1 - 540) or Hours (1 - 9). The default setting is 300 seconds.
box to allow TFTP traffic through the Firewall using its
box to allow SIP traffic through the Firewall using its
field to set the following parameters:
radio button to enable the stateful checks of DHCP packet traffic