5 - 60 WiNG 5 Access Point System Reference Guide
20. Set the following session parameters:
Name
IP Address
IP
Local Session ID
MTU
Figure 5-30 Network - L2TPv3 screen, Add T2TP Peer Configuration
Define a 31 character maximum name of this tunnel session. After a successful
tunnel connection and establishment, the session is created. Each session
name represents a single data stream.
Specify the IP address used to be as tunnel source ip address. If not specified,
the tunnel source IP address is selected automatically based on the tunnel peer
IP address. This address is applicable only for initiating the tunnel. When
responding to incoming tunnel create requests, it would use the IP address on
which it had received the tunnel create request.
Set the IP address of an L2TP tunnel peer. This is the peer allowed to establish
the tunnel.
Set the numeric identifier for the tunnel session. This is the pseudowire ID for
the session. This pseudowire ID is sent in session establishment message to
the L2TP peer.
Define the session maximum transmission unit (MTU) as the size (in bytes) of
the largest protocol data unit the layer can pass between tunnel peers in this
session. A larger MTU means processing fewer packets for the same amount
of data.