Severity: Error Alert Category: Critical - Other Serviceable: Yes Cim Information: Prefix: Plat And Id; Snmp Trap Id: 50 - Lenovo System x3650 M5 Installation And Service Manual

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

8007020f-2582ffff • 8007021b-0301ffff
3.
If the problem remains, contact your service
representative.
8007020f-2582ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (I/O Resources)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020f2582ffff or
0x8007020f2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522

SNMP Trap ID: 50

Automatically notify Support: No
User response: Complete the following step to solve
PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
System Settings -> Device and I/O ports "PCI 64
3.
bit Resource"
choose "enable"
4.
80070214-2201ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (TPM Lock)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702142201ffff or
0x800702142201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1. Update the server firmware (see Recovering the
server firmware).
2.
If the problem persists, (trained technician only)
replace the system board (see Removing the system
board and Installing the system board).
378
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
80070219-0701ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (SysBrd Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702190701ffff or
0x800702190701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for an error LED on the system board.
2.
Check the system-event log.
3.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
4.
Replace any failing device.
5.
(Trained technician only) Replace the system board.
8007021b-0301ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (CPU 1 QPILinkErr)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007021b0301ffff or
0x8007021b0301ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for a server firmware update.
2.
Make sure that the installed microprocessors are
compatible.
3.
Make sure the microprocessor 2 expansion board is
installed correctly (see Installing the microprocessor
2 expansion board).
4.
(Trained technician only) Replace microprocessor 2.

Advertisement

Table of Contents
loading

Table of Contents