Lenovo System x3650 M5 Installation And Service Manual page 480

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

806f050d-040cffff • 806f050d-040effff
implementation has detected that an Array is Critical.
May also be shown as 806f050d040bffff or
0x806f050d040bffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
Check backplane cable connection.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
6.
lit status LED.
806f050d-040cffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 12)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d040cffff or
0x806f050d040cffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
466
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
806f050d-040dffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 13)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d040dffff or
0x806f050d040dffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-040effff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 14)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d040effff or
0x806f050d040effff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.

Advertisement

Table of Contents
loading

Table of Contents