implementation has detected an Interconnect
Configuration Error.
May also be shown as 806f011b250bffff or
0x806f011b250bffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: If the specified sensor is front USB
connector, reset the front USB cable on the system
board. If the specified sensor is front video connector,
reset the front video cable in the system board. If the
specified sensor is PwrPaddle cable, complete the
following steps until problem is solved:
1.
Reseat the power paddle cable on the system
board.
2.
Replace the power paddle cable.
3.
(Trained technician only) Replace the supercap n.
(n = supercap number)
4.
(Trained technician only) Replace the system board.
806f0123-2101ffff
Reboot of system
[ComputerSystemElementName]
initiated by [WatchdogElementName].
(IPMI Watchdog)
Explanation: This message is for the use case when an
implementation has detected a Reboot by a Watchdog
occurred.
May also be shown as 806f01232101ffff or
0x806f01232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-0c01ffff
[ManagedElementName] detected
as absent. (Front Panel)
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
May also be shown as 806f01250c01ffff or
0x806f01250c01ffff
Severity: Info
806f0123-2101ffff • 806f0125-100bffff
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-1001ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
May also be shown as 806f01251001ffff or
0x806f01251001ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-1002ffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
May also be shown as 806f01251002ffff or
0x806f01251002ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0125-100bffff
Explanation: This message is for the use case when an
implementation has detected a Managed Element is
Absent.
May also be shown as 806f0125100bffff or
0x806f0125100bffff
Severity: Info
Appendix A. Integrated management module II (IMM2) error messages
[ManagedElementName] detected
as absent. (PCI Riser 1)
[ManagedElementName] detected
as absent. (PCI Riser 2)
[ManagedElementName] detected
as absent. (PDB Card)