May also be shown as 806f0a0c2017ffff or
0x806f0a0c2017ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
in place and correctly installed, and that the server
cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2018ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 24)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2018ffff or
0x806f0a0c2018ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Make sure that the fans are operating, that there are
no obstructions to the airflow, that the air baffles are
in place and correctly installed, and that the server
cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2018ffff • 81010002-0701ffff
806f0a13-0301ffff
Explanation: This message is for the use case when an
implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130301ffff or
0x806f0a130301ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Reseat the microprocessor, and then restart the
server.
2.
Replace microprocessor n. (n = microprocessor
number)
806f0a13-0302ffff
Explanation: This message is for the use case when an
implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130302ffff or
0x806f0a130302ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Reseat the microprocessor, and then restart the
server.
2.
Replace microprocessor n. (n = microprocessor
number)
81010002-0701ffff
Explanation: This message is for the use case when an
implementation has detected a Lower Non-critical
sensor going low has deasserted.
May also be shown as 810100020701ffff or
0x810100020701ffff
Appendix A. Integrated management module II (IMM2) error messages
A Fatal Bus Error has occurred on
system [ComputerSystemElementName].
(CPU 1 PECI)
A Fatal Bus Error has occurred on
system [ComputerSystemElementName].
(CPU 2 PECI)
Numeric sensor
[NumericSensorElementName] going
low (lower non-critical) has deasserted.
(CMOS Battery)