Lenovo System x3650 M5 Installation And Service Manual page 507

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

806f0813-2584ffff
A Uncorrectable Bus Error has
occurred on system
[ComputerSystemElementName]. (CPUs)
Explanation: This message is for the use case when an
implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132584ffff or
0x806f08132584ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0240
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check the system-event log.
2.
(Trained technician only) Remove the failing
microprocessor from the system board (see
Removing a microprocessor and heat sink).
3.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
4.
Make sure that the two microprocessors are
matching.
5.
(Trained technician only) Replace the system board.
806f0823-2101ffff
Watchdog Timer interrupt occurred
for [WatchdogElementName]. (IPMI
Watchdog)
Explanation: This message is for the use case when an
implementation has detected a Watchdog Timer
interrupt occurred.
May also be shown as 806f08232101ffff or
0x806f08232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0376
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0813-2584ffff • 806f090c-2003ffff
806f090c-2001ffff
Explanation: This message is for the use case when an
implementation has detected Memory has been
Throttled.
May also be shown as 806f090c2001ffff or
0x806f090c2001ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2002ffff
Explanation: This message is for the use case when an
implementation has detected Memory has been
Throttled.
May also be shown as 806f090c2002ffff or
0x806f090c2002ffff
Severity: Warning
Alert Category: System - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0142
SNMP Trap ID: 22
Automatically notify Support: No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2003ffff
Explanation: This message is for the use case when an
implementation has detected Memory has been
Throttled.
May also be shown as 806f090c2003ffff or
0x806f090c2003ffff
Severity: Warning
Alert Category: System - Other
Appendix A. Integrated management module II (IMM2) error messages
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]
Throttled. (DIMM 1)
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]
Throttled. (DIMM 2)
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName]
Throttled. (DIMM 3)
493

Advertisement

Table of Contents
loading

Table of Contents