Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0408ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 8)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0408ffff or
0x806f050d0408ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
Replace the RAID adapter.
5.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0409ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 9)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
806f050d-0408ffff • 806f050d-040bffff
May also be shown as 806f050d0409ffff or
0x806f050d0409ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-040affff
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d040affff or
0x806f050d040affff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-040bffff
Explanation: This message is for the use case when an
Appendix A. Integrated management module II (IMM2) error messages
Array
[ComputerSystemElementName] is in
critical condition. (Drive 10)
Array
[ComputerSystemElementName] is in
critical condition. (Drive 11)
465