User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0416ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
22)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0416ffff or
0x806f020d0416ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0417ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
23)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0417ffff or
0x806f020d0417ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
806f020d-0416ffff • 806f020d-0419ffff
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0418ffff
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0418ffff or
0x806f020d0418ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0419ffff
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0419ffff or
0x806f020d0419ffff
Severity: Warning
Alert Category: System - Predicted Failure
Appendix A. Integrated management module II (IMM2) error messages
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
24)
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
25)
427