Run The Hard Disk Drive Diagnostic Test On Drive N; Reseat The Following Components: A. Hard Disk Drive (Wait 1 Minute Or More Before Reinstalling The Drive) B. Cable From The System Board To The Backplane; Severity: Error Alert Category: Critical - Other Serviceable: Yes Cim Information: Prefix: Plat And Id; Snmp Trap Id: 0 - Lenovo System x3650 M5 Installation And Service Manual

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

80070301-2c01ffff • 80070608-0a01ffff
2.
Check the ambient temperature. You must be
operating within the specifications (see Server
Features and specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
80070301-2c01ffff
Sensor [SensorElementName] has
transitioned to non-recoverable from a
less severe state. (ML2 OverTemp)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable from less severe.
May also be shown as 800703012c01ffff or
0x800703012c01ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524

SNMP Trap ID: 0

Automatically notify Support: No
User response:
Make sure that the fans are operating, that there
1.
are no obstructions to the airflow (front and rear of
the server), that the air baffle is in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications (see Server
Features and specifications for more information).
3.
Make sure that the heat sink for microprocessor n.
4.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
8007030d-2582ffff
Sensor [SensorElementName] has
transitioned to non-recoverable from a
less severe state. (RAID Vol State)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable from less severe.
May also be shown as 8007030d2582ffff or
0x8007030d2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 50
Automatically notify Support: No
User response:
380
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
1.

Run the hard disk drive diagnostic test on drive n.

2.
Reseat the following components: a. Hard disk
drive (wait 1 minute or more before reinstalling the
drive) b. Cable from the system board to the
backplane
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive b. Cable from the system board to
the backplane c. Hard disk drive backplane (n =
hard disk drive number)
80070608-0a01ffff
Sensor [SensorElementName] has
transitioned to non-recoverable.
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706080a01ffff or
0x800706080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: If the specified sensor is PS n 12V OC
Fault, complete the following steps until the problem is
solved:
1.
Use the IBM Power Configurator utility to
determine current system power consumption. For
more information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
2.
Follow actions in "Power Problems and Solving
Power Problems".
If the specified sensor is PS n 12V OV Fault, complete
the following steps until the problem is solved:
Check power supply n LED.
1.
Remove the failing power supply.
2.
(Trained technician only) Replace the system board.
3.
(n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving
Power Problems".
4.
(Trained technician only) Replace the system board.
(n = power supply number)