Lenovo System x3650 M5 Installation And Service Manual page 628

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

I.3818002 • I.580A4
User response: Complete the following steps:
1.
Reboot the system. Will come up on backup UEFI
image. Update the primary UEFI image.
2.
If error does not persist no additional recovery
action is required.
3.
If error persists, or boot is unsuccessful, (Trained
service technician only) Replace the system board.
I.3818002
[I.3818002]
Explanation: The firmware image capsule signature
for the non-booted flash bank is invalid. Opposite Bank
CRTM Capsule Update Signature Invalid
Severity: Info
User response: Complete the following steps:
1.
Update the backup UEFI image.
2.
If error does not persist no additional recovery
action is required.
3.
If error persists, or boot is unsuccessful, (Trained
service technician only) Replace the system board.
I.3818003
[I.3818003]
Explanation: The CRTM flash driver could not lock
the secure flash region. CRTM Could not lock secure
flash region
Severity: Info
User response: Complete the following steps:
1.
If system failed to boot successfully, DC cycle the
system.
2.
If system boots to F1 setup, update the UEFI image
and reset bank to primary (if required). If the
system boots without error, recovery is complete
and no additional action is required.
3.
If system fails to boot, or if the firmware update
attempt fails, (trained service technician only)
replace the system board.
I.3818009
[I.3818009]
Explanation: The TPM could not be properly
initialized. TPMINIT: Fail to initialize TPM chip.
Severity: Info
User response: Complete the following steps:
1.
Check the IBM support site for an applicable
service bulletin or firmware update that applies to
this error.
2.
Reboot the system.
3.
If the error continues, replace the system-board
assembly (see Removing the system-board
assembly and Installing the system-board
assembly).
614
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
I.3868000
[I.3868000]
Explanation: IFM: System reset performed to reset
adapters. IFM: System reset performed to reset adapters
Severity: Info
User response: Complete the following steps:
Information only; no action is required.
1.
I.3868003
[I.3868003]
Explanation: IFM: Configuration to large for
compatibility mode. IFM: Configuration too large for
compatibility mode
Severity: Info
User response: Complete the following steps:
Information only; no action is required.
1.
I.5100B
[I.5100B]
Explanation: An unqualified DIMM serial number has
been detected: serial number % found in slot % of
memory card %. Unqualified DIMM Serial Number
Detected
Severity: Info
User response: Complete the following steps:
1.
If this information event is logged in the IMM
event log, the server does not have qualified
memory installed.
2.
The memory installed may not be covered under
warranty.
3.
Without qualified memory, speeds supported above
industry standards will not be enabled.
4.
Please contact your Local Sales Representative or
Authorized Business Partner to order qualified
memory to replace the unqualified DIMM(s).
5. After you intall qualified memory and power up
the server, check to make sure this informational
event is not logged again.
I.58015
[I.58015]
Explanation: Memory spare copy initiated. Spare
Copy Started
Severity: Info
User response: Complete the following steps:
1.
Information only; no action is required.
I.580A4
[I.580A4]
Explanation: Memory population change detected.
DIMM Population Change Detected
Severity: Info
User response: Complete the following steps:

Advertisement

Table of Contents
loading

Table of Contents