Lenovo System x3650 M5 Installation And Service Manual page 321

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

Power / configuration
cables
SAS 0 SAS 1
Figure 269. Cable routing
9. If you removed the fan cage, install it. (See "Replacing the fan cage assembly"
on page 176).
10. Insert the hard disk drives and the fillers the rest of the way into the bays.
Installing a 8x 2.5-inch hot-swap HDD assembly with expander
kit
Use this information to install a 8x 2.5-inch hot-swap HDD assembly kit with
expander.
About this task
You can install a Lenovo System x3650 M5 8x 2.5-inch hot-swap HDD assembly
with expander kit to add eight additional 2.5-inch hot-swap hard disk drives in the
server. See http://www.ibm.com/systems/info/x86servers/serverproven/compat/
us/ for a list of supported optional devices. To order a 8x 2.5-inch hot-swap HDD
assembly kit with expander, contact your sales representative or reseller.
The 8x 2.5-inch hot-swap HDD assembly with expander kit contains the following
components:
v Eight 2.5-inch HDD fillers
v One expander
v Two power/configuration cables (230 mm)
v One power/configuration cable (260 mm)
SAS 1 SAS 0
SAS 0 SAS 1
Chapter 5. Removing and replacing components
SAS signal cables
307

Advertisement

Table of Contents
loading

Table of Contents