2.
Check the IBM support site for an applicable
service bulletin or firmware update for the system
or adapter that applies to this error.
3.
Replace the I/O device or PCIe adapter
4.
(Trained technician only)Replace the system board
reported in the error.
S.680B8
[S.680B8]
Explanation: Internal QPI Link Failure Detected.
Internal QPI Link Failure Detected
Severity: Error
User response: Complete the following steps:
1.
Check the IBM support site for an applicable
service bulletin or firmware update that applies to
this error.
2.
Inspect the processor socket for foreign debris or
damage. If debris is found, remove the debris.
3.
(Trained technician only)If error recurs, or socket
damage is found, replace the system board
4.
(Trained Service Technician Only) Replace the
processor.
S.680B9
[S.680B9]
Explanation: External QPI Link Failure Detected.
External QPI Link Failure Detected
Severity: Error
User response: Complete the following steps:
1.
Check the IBM support site for an applicable
service bulletin or firmware update that applies to
this error.
2.
Inspect the processor socket for foreign debris or
damage. If debris is found, remove the debris.
3.
(Trained technician only)If error recurs, or socket
damage is found, replace the system board
W.11004
[W.11004]
Explanation: A processor within the system has failed
the BIST. Processor Self Test Failure Detected
Severity: Error
User response: Complete the following steps:
1.
If the processor or firmware was just updated,
check the IBM support site for an applicable service
bulletin or firmware update that applies to this
processor error.
2.
(Trained service technician only) If there are
multiple Processor's, swap Processor's to move
affected Processor to another Processor socket and
retry. If problem follows the affected Processor, or
this is a single Processor processor. Inspect the
processor socket on each processor removal and
replace system board first if the processor socket is
damaged or mis-aligned pins are found.
3. (Trained Service technician only) Inspect Processor
socket on each Processor removal and replace
system board first if damaged or mis-aligned pins
are found. Replace the system board.
W.3048006
[W.3048006]
Explanation: UEFI has booted from the backup flash
bank due to an Automatic Boot Recovery (ABR) event.
Automated Boot Recovery, Booting Backup UEFI Image
Severity: Warning
User response: Complete the following steps:
1.
Check the IBM support site for an applicable
service bulletin or firmware update that applies to
this error.
2.
Update the primary UEFI image.
3.
Replace the system board.
W.305000A
[W.305000A]
Explanation: An invalid date and time have been
detected. RTC Date and Time Incorrect
Severity: Warning
User response: Complete the following steps:
1.
Check IMM/chassis event log. This event should
immediately precede 0068002 error. Resolve that
event or any other battery related errors.
2.
Use F1 Setup to reset date and time. If problem
returns after a system reset, replace CMOS battery.
3.
If problem persists then check IBM support site for
an applicable service bulletin or firmware update
that applies to this error.
4.
(Trained service technician only) Replace the
system board.
W.3058009
[W.3058009]
Explanation: DRIVER HEALTH PROTOCOL: Missing
Configuration. Requires Change Settings From F1.
DRIVER HEALTH PROTOCOL: Missing Configuration.
Requires Change Settings From F1
Severity: Warning
User response: Complete the following steps:
Go to F1 Setup > System Settings > Settings >
1.
Driver Health Status List and find a
driver/controller reporting Configuration Required
status.
Search for the driver menu from System Settings
2.
and change settings appropriately.
Save settings and restart system.
3.
Appendix B. UEFI/POST diagnostic codes
S.680B8 • W.3058009
619