Dsa Nvidia Gpu Test Results - Lenovo System x3650 M5 Installation And Service Manual

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

202-803-000 • 202-902-000
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
v
Latest level of BMC/IMM
202-803-000
MemStr Test Aborted
Explanation: User pressed Ctrl-C.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
v
Latest level of DSA
v
Latest level of BMC/IMM
202-901-000
MemStr Test Failed
Explanation: Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Execute the standard DSA memory diagnostics to
validate all memory.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Turn off the system and disconnect it from power.
4. Reseat the memory cards and DIMMs.
5. Reconnect the system to power and turn the system
on.
6. Run the test again.
7. Execute the standard DSA memory diagnostics to
validate all memory.
8. If the failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v

DSA Nvidia GPU test results

The following messages can result when you run the Nvidia GPU test.
674
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
202-902-000
MemStr Test Failed
Explanation: Memory size is insufficient to run the
test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Ensure that all memory is enabled by checking the
"Available System Memory" in the "Resource
Utilization" section of the DSA Diagnostic Event log.
2. If necessary, access the Configuration/Setup Utility
program by pressing F1 during system boot and
enable all memory.
3. Make sure that the DSA Diagnostic code is at the
latest level.
4. Run the test again.
5. Execute the standard DSA memory diagnostics to
validate all memory.
6. If the failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
v
Latest level of DSA
Latest level of BMC/IMM
v

Advertisement

Table of Contents
loading