1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0411ffff
Array
[ComputerSystemElementName] has
failed. (Drive 17)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0411ffff or
0x806f060d0411ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0412ffff
Array
[ComputerSystemElementName] has
failed. (Drive 18)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0412ffff or
0x806f060d0412ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
806f060d-0411ffff • 806f060d-0414ffff
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0413ffff
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0413ffff or
0x806f060d0413ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0414ffff
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0414ffff or
0x806f060d0414ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
Appendix A. Integrated management module II (IMM2) error messages
Array
[ComputerSystemElementName] has
failed. (Drive 19)
Array
[ComputerSystemElementName] has
failed. (Drive 20)
477