Lenovo System x3650 M5 Installation And Service Manual page 460

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

806f0313-1701ffff • 806f040c-2002ffff
CIM Information: Prefix: PLAT and ID: 0170
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f0313-1701ffff
A software NMI has occurred on
system [ComputerSystemElementName].
(NMI State)
Explanation: This message is for the use case when an
implementation has detected a Software NMI.
May also be shown as 806f03131701ffff or
0x806f03131701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0228
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check the device driver.
2.
Reinstall the device driver.
Update all device drivers to the latest level.
3.
Update the firmware (UEFI and IMM).
4.
806f0323-2101ffff
Power cycle of system
[ComputerSystemElementName]
initiated by watchdog
[WatchdogElementName]. (IPMI
Watchdog)
Explanation: This message is for the use case when an
implementation has detected a Power Cycle by
Watchdog occurred.
May also be shown as 806f03232101ffff or
0x806f03232101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0374
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
446
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
806f040c-2001ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 1)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2001ffff or
0x806f040c2001ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2002ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 2)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2002ffff or
0x806f040c2002ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this

Advertisement

Table of Contents
loading

Table of Contents