806f050d-041bffff • 806f050d-041effff
806f050d-041bffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 27)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d041bffff or
0x806f050d041bffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-041cffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 28)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d041cffff or
0x806f050d041cffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
470
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
806f050d-041dffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 29)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d041dffff or
0x806f050d041dffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-041effff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 30)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d041effff or
0x806f050d041effff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.

Advertisement

Table of Contents
loading

Table of Contents