Lenovo System x3650 M5 Installation And Service Manual page 390

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

80070204-0a02ffff • 8007020c-2502ffff
Automatically notify Support: No
User response:
Make sure that there are no obstructions, such as
1.
bundled cables, to the airflow from the
power-supply fan.
Replace power supply n. (n = power supply
2.
number)
80070204-0a02ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 2 Fan Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702040a02ffff or
0x800702040a02ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the
power-supply fan.
Replace power supply n. (n = power supply
2.
number)
80070208-0a01ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 1 Therm Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702080a01ffff or
0x800702080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the
power-supply fan.
376
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
2.
Use the IBM Power Configurator utility to ensure
current system power consumption is under
limitation. For more information and to download
the utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
3.
Replace power supply n. (n = power supply
number)
80070208-0a02ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 2 Therm Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702080a02ffff or
0x800702080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the
power-supply fan.
2.
Use the IBM Power Configurator utility to ensure
current system power consumption is under
limitation. For more information and to download
the utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
3.
Replace power supply n. (n = power supply
number)
8007020c-2502ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (nvDIMM 02 Status)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020c2502ffff or
0x8007020c2502ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: None