Lenovo System x3650 M5 Installation And Service Manual page 465

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2012ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 18)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2012ffff or
0x806f040c2012ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2013ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 19)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2013ffff or
0x806f040c2013ffff
Severity: Info
806f040c-2012ffff • 806f040c-2015ffff
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
Make sure the DIMM is installed correctly.
1.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
Check the IBM support website for an applicable
3.
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2014ffff
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2014ffff or
0x806f040c2014ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
Make sure the DIMM is installed correctly.
1.
If the DIMM was disabled because of a memory
2.
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
Check the IBM support website for an applicable
3.
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2015ffff
Explanation: This message is for the use case when an
Appendix A. Integrated management module II (IMM2) error messages
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 20)
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 21)
451

Advertisement

Table of Contents
loading

Table of Contents