Lenovo System x3650 M5 Installation And Service Manual page 391

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

8007020c-2505ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (nvDIMM 05 Status)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020c2505ffff or
0x8007020c2505ffff
Automatically notify Support: No
User response: None
8007020c-2508ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (nvDIMM 08 Status)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020c2508ffff or
0x8007020c2508ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: None
8007020c-250bffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (nvDIMM 11 Status)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020c250bffff or
0x8007020c250bffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
8007020c-2505ffff • 8007020f-2201ffff
Automatically notify Support: No
User response: None
8007020d-2582ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020d2582ffff or
0x8007020d2582ffff
Automatically notify Support: No
User response:
1.
2.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive b. Cable from the system board to
the backplane c. Hard disk drive backplane (n =
hard disk drive number)
8007020f-2201ffff
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020f2201ffff or
0x8007020f2201ffff
Automatically notify Support: No
User response:
If enabling TXT is not required, disable TXT from
1.
the Setup Utility.
2.
If enabling TXT is required, verify that the TPM is
enabled and activated from the Setup Utility.
Appendix A. Integrated management module II (IMM2) error messages
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (RAID Vol State)
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (TXT ACM Module)
377

Advertisement

Table of Contents
loading

Table of Contents