Lenovo System x3650 M5 Installation And Service Manual page 492

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

806f060d-0415ffff • 806f060d-0418ffff
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0415ffff
Array
[ComputerSystemElementName] has
failed. (Drive 21)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0415ffff or
0x806f060d0415ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0416ffff
Array
[ComputerSystemElementName] has
failed. (Drive 22)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0416ffff or
0x806f060d0416ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
478
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0417ffff
Array
[ComputerSystemElementName] has
failed. (Drive 23)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0417ffff or
0x806f060d0417ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0418ffff
Array
[ComputerSystemElementName] has
failed. (Drive 24)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0418ffff or
0x806f060d0418ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response: