Lenovo System x3650 M5 Installation And Service Manual page 411

Hide thumbs Also See for System x3650 M5:
Table of Contents

Advertisement

2.
Make sure that the heat sink for microprocessor n
is installed correctly.
3.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0107-0302ffff
An Over-Temperature Condition
has been detected on
[ProcessorElementName]. (CPU 2)
Explanation: This message is for the use case when an
implementation has detected an Over-Temperature
Condition Detected for Processor.
May also be shown as 806f01070302ffff or
0x806f01070302ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0036
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating. There are no
obstructions to the airflow (front and rear of the
server), the air baffles are in place and correctly
installed, and the server cover is installed and
completely closed.
2.
Make sure that the heat sink for microprocessor n
is installed correctly.
3.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0108-0a01ffff
[PowerSupplyElementName] has
Failed. (Power Supply 1)
Explanation: This message is for the use case when an
implementation has detected a Power Supply has
failed.
May also be shown as 806f01080a01ffff or
0x806f01080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
Reseat power supply n.
1.
If the power-on LED is not lit and the
2.
power-supply error LED is lit, replace power supply
n.
806f0107-0302ffff • 806f010c-2001ffff
3.
If both the power-on LED and the power-supply
error LED are not lit, see Power problems for more
information. (n = power supply number)
806f0108-0a02ffff
Explanation: This message is for the use case when an
implementation has detected a Power Supply has
failed.
May also be shown as 806f01080a02ffff or
0x806f01080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
1.
Reseat power supply n.
If the power-on LED is not lit and the
2.
power-supply error LED is lit, replace power supply
n.
If both the power-on LED and the power-supply
3.
error LED are not lit, see Power problems for more
information. (n = power supply number)
806f0109-1301ffff
Explanation: This message is for the use case when an
implementation has detected a Power Unit that has
been power cycled.
May also be shown as 806f01091301ffff or
0x806f01091301ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0108
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
806f010c-2001ffff
Explanation: This message is for the use case when an
implementation has detected a Memory uncorrectable
error.
Appendix A. Integrated management module II (IMM2) error messages
[PowerSupplyElementName] has
Failed. (Power Supply 2)
[PowerSupplyElementName] has
been Power Cycled. (Host Power)
Uncorrectable error detected for
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 1)
397