806f050d-0413ffff • 806f050d-0416ffff
806f050d-0413ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 19)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0413ffff or
0x806f050d0413ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0414ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 20)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0414ffff or
0x806f050d0414ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
468
Lenovo System x3650 M5 Type 5462: Installation and Service Guide
806f050d-0415ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 21)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0415ffff or
0x806f050d0415ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0416ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 22)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0416ffff or
0x806f050d0416ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.

Advertisement