Main Calibration Screen - KEPCO BOP 1000W Operator's Manual

High power bipolar power supply
Hide thumbs Also See for BOP 1000W:
Table of Contents

Advertisement

2. Enter the password (see PAR. 3.2.4.4), and press
screen (Figure 4-3) which includes explanations for the following function keys:
!
- VOLTAGE - Selects the voltage calibration of the BOP.
@
- CURRENT - Starts the calibration for the BOP in current mode.
#
- EXTRL CONTROLS - Selects input and output signal calibration used for multiple
units and the external protection.
$
- SAVE - Save New Calibration Setting. The information in the DATE field is saved
with the Calibration.
%
or ENTER - EXIT
3. Press either
multiple units refer to the Instruction Manual Included with the associated parallel or series
connection cable kit. The LCD shows the explanations for the following function keys:
!
- INTERNAL - Selects the voltage calibration of the BOP.
@
- GAIN - Starts the calibration of the external gain mode of the power supply.
#
- EXTERNAL - Starts the external reference calibration.
$
- PROTECT - Starts the protection limits calibration of the power supply.
%
or ENTER - EXIT - Exit Voltage or Current Calibration
4. Pressing
BOP-1K 080709
FIGURE 4-3.

MAIN CALIBRATION SCREEN

!
@
or
to initiate Voltage or Current calibration, respectively. To calibrate
!
@
#
$
,
,
, or
displays following explanations for the function keys:
!
, The LCD shows main calibration
4-11