NUMBER
CONNECTOR/TERMINAL
(FIGURE 2-1)
(REFERENCE DESIGNATOR)
IEEE 1118 (BITBUS)
1
PORT
(connector A1J4)
TRIGGER
2
(connector A1J3)
IEEE 488 (GPIB) PORT
3
(connector A1J6)
ANALOG I/O PORT
4
(connector A2A5J6)
PARALLEL/SERIAL
CONTROL PORT
5
(connectors A2A5J3, IN
and A2A5J4, OUT)
PARALLEL/SERIAL
PROTECT PORT
6
(connectors A2A5J1, IN
and A2A5J2 OUT)
EXT PROTECT PORT
7
(connector A2A5J7)
INPUT connector
8
(connector A7J1)
Monitor and Sensing
9
terminal block
(terminal block A7A1TB1)
10
COMMON
11
(terminal A7J3)
OUTPUT
12
(terminal A7J2)
RS232 PORT
13
(connector A1J5)
2-2
TABLE 2-1. REAR PANEL CONNECTOR FUNCTIONS
Used for multiple identical BOP master/slave parallel, and series and series-parallel
(1)
configurations (refer to PAR. 2.8, see Table 2-2).
May be used to initiate BOP output. (See Table 2-3.)
Used for Remote control of the BOP via the IEEE 488 (GPIB) interface (See Table
2-11.)
Provides interface for analog input/output signals. (See Table 2-10.)
Provides interconnections used to control parallel or serial configurations of identi-
cal BOP's as a single power supply (see Table 2-7 for A2A5J3, IN and Table 2-6 for
A2A5J4, OUT).
Provides interconnections used to control protection shutdown of power supplies
connected in parallel or serial configurations (see Table 2-8 for A2A5J1, IN and
Table 2-9 for A2A5J2, OUT).
Provides means for controlling protection via external circuitry and provides status
flags to external circuitry. (See Table 2-4.)
Connects source power to unit.
Pin 1 - Line (or Line 1 without Neutral connection)
Pin 2 - Neutral (or Line 2 without Neutral connection)
Pin 3 - Ground (Protective conductor terminal)
Terminal block provides external connections as follows:
OUT S: Sense line connection to load (compensate for voltage drop on connections
to load.) See PAR. 2.5.6 and 2.5.7 (Terminal 2).
OUT MON: Monitor connection used to monitor output voltage at power terminals
and to implement local sensing (Terminal 3).
GND NET: Grounding network connection (Terminal 4). See PAR. 2.5.3.1.
GND: Chassis ground connection (Terminal 5).
COM MON: Monitor return connection (Terminal 6). Used to monitor output voltage
at power terminals and to implement local sensing.
COM S: Sense line return connection from load (Terminal 7) See PAR. 2.5.6 and
2.5.7
terminals
Frame or chassis terminals
Power output return from load.
Power output connection to load.
Used for Remote control of the BOP via the RS 232 serial interface. (See Table 2-5
for details.)
FUNCTION