TABLE 3-13. ERROR MESSAGE EXPLANATIONS (CONTINUED)
ERROR MESSAGE
Save Disabled, Request ignored
EXTERNAL MODE enabled.
F2 Key not valid
Password incorrect
F3 - Invalid
F4 - Invalid
Series or Parallel when not
STANDALONE
Calibration invalid - Multiple Unit
BITBUS option must be Disabled
External Reference Waveform not
accessible
External Mode - Waveform not
accessible
External Limits - Waveform not
accessible
Empty Entry - use F2 instead
No Room to insert - delete a segment.
Unable to delete segment.
Only EDIT allowed on Entry.
MODE incorrect - Please Change
Unit in STANDBY - Please Change
Can not delete Single Segment - use
F1 to Change
Can not delete the empty segment.
Entry not Empty, Use F1 to change.
Under Minimum allowed value
Frequency has no sign
Use F5 to stop waveform.
3.4

ANALOG REMOTE MODE PROGRAMMING

The BOP can be programmed remotely using analog signals applied to the remote Analog I/O
port at the rear panel (see Figure 2-1 and Table 2-10). Analog remote programming allows the
user to 1) establish voltage or current mode (PAR. 3.4.2), 2) control the main channel using the
3-34
Save Display Change is disabled. From power-up screen, press
settings to enable.
MODE key does not function while Mode is being controlled externally. Press
light External Mode and change to Disable.
F2 only works when labeled. key was probably pressed inadvertently.
Enter the correct password and press
recovered, refer to PAR. 3.6.3.12.1 to reset to factory defaults.
Setup Menu
#
only works when labeled. Key was probably press inadvertently.
$
only works when labeled. Key was probably press inadvertently.
Master/Slave Menu
Mismatch between Unit type and Connection type. Automatically reverts to
Unit type: Standalone, Connection Type: standalone.
Consult Factory.
Change CIIL mode to SCPI. From power-up screen press
!
mat, press
, highlight SCPI, press
cycle BOP off, then on.
Waveform Menu
Reference Input must be set to Internal for waveforms to be executed. Press
!
Reference Input, press
highlight Internal, press
External Mode must be disabled for waveforms to be executed. Press
!
nal Mode, press
highlight Disable, press
Protection Limit must be set to Internal for waveforms to be executed. Press
!
Protection Limit, press
highlight Internal, press
Empty location cannot be modified using
No more than 10 segments are allowed in a waveform.
Try again. If still unable to delete segment, contact factory. for RMA.
When viewing waveform, if name, count or protection levels are highlighted, press
@
!
modify the setting.
and
A voltage waveform was executed while the unit was in current mode or a current
waveform was executed while the unit was in voltage mode. Press MODE key to change to
correct mode, press STANDBY key to set output on then press
Output must be on for the waveform to be executed. press STANDBY key to set output on
$
then press
to run the waveform
Waveform must have at least one segment.
"End of Segments" was highlighted when
segment and try again.
@
pressed while a previously saved waveform was highlighted. Use
@
highlight Empty and press
Frequency or period was too small.
+/- key is not functional when modifying frequency.
$
not valid when waveform already executing.
EXPLANATION
!
. If password has been lost and can not be
%
$
$
, then press
to save for power-up, then
$
, then
$
%
, then
.
$
, then
!
@
Press
to start new waveform.
are not functional with these parameters.
#
- Erase was pressed. Move highlight to valid
for a new waveform.
%
, highlight password
$
, high-
highlight Interface Data For-
$
highlight
%
.
$
highlight Exter-
$
highlight
%
.
!
to
$
to run the waveform
!
to modify or
BOP HIPWR 080709