Advertisement

Quick Links

Q U I C K S T A R T G U I D E
KEPCO
This guide gives a brief introduction to the BOP 1KW-G
Power supply, shows simple load connections, and
allows you to verify the power supply is working. The
guide also shows you how to perform the most com-
monly used functions.
ACCESSING MANUALS.
Firmware Version (see below), then download the BOP
1KW-G Operator's Manual from
www.kepcopower.com/support/opmanls.htm#bop-g
Refer to the BOP 1KW-G Operator's Manual for full
specifications, installation considerations and oper-
ating instructions. The BOP 1KW-G Operator's Man-
ual also includes a full description of the digital
interfaces and the SCPI command language.
NOTE: Download the latest version of this guide at:
www.kepcopower.com/support/opmanls.htm#bop-g
I Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
II Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
III Equipment Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
IV Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
V Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
VI Preliminary Operational Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
VII Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Input Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Load Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Local Sensing (Factory Default). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Remote Sensing Select. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Analog I/O Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Trigger Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GPIB Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
RS 232 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
VIII Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Power-up Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Turning The Power Supply On. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Reset Power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Normal Power-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power Supply Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Voltage and Current Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting Voltage or Current Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Voltage/Current Protect Limits (Limit Channel Software Limits). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Software Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maximum/Minimum Protection Limits (Software-controlled). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Determining How the Unit Responds when Output is OFF (Load Type). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Configure Load Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Enabling/disabling Output Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
IX Additional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102
032818
An ISO 9001 Company.
BOP 1KW-G POWER SUPPLY
First determine your
CONTENTS
http://www.kepcopower.com   email: hq@kepcopower.com
228-1898 REV 1
FIRMWARE VERSION. With no load connected
and power off, use either the GPIB port or RS 232
port (see page 6) to accept remote commands.
If necessary, refer to "Reset Power-up" on page 8
and Figure 5 to configure the GPIB address (default
is 6) or configure the RS 232 baud rate (default is
9600).
Apply power to the unit and send *IDN? query. The
unit responds with a character string containing the
following fields:
<Manufacturer>,<Model Voltage-
Current Calibration Date>,<Serial Number>, <Firm-
ware Version> e.g., KEPCO, BOP1KW 20-50 09/30/
2001,123456,4.01.
ACCESSING DRIVERS. Drivers are accessed
from
www.kepcopower.com/drivers/drivers-dl3.htm.
BOP
1KW-G
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOP 1KW-G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KEPCO BOP 1KW-G

  • Page 1: Table Of Contents

    IX Additional Features ................13 KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102...
  • Page 2: I Description

    Perform the “Prelimi- nary Operational Check” on page 5. If any indication KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1898 REV 1...
  • Page 3 (Tyco-Amp 207470-1) Dsub 15 pin male 142-0449 (Amphenol 17S-DA15P) FIGURE 1. BOP-G OUTPUT CHARACTERISTICS KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818 228-1898 REV 1...
  • Page 4: Accessories

    INDICATES THE POSSIBILITY OF BODILY INJURY OR DEATH. CAUTION INDICATES THE POSSIBILITY OF EQUIPMENT DAMAGE. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1898 REV 1...
  • Page 5: Preliminary Operational Check

    Line cords available as leads (after removing the factory-installed local accessories are listed in Table 3. Plug the source KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818...
  • Page 6: Local Sensing (Factory Default)

    Output analogs FIGURE 2. BOP-G 1KW SERIES, FRONT PANEL CONTROLS AND INDICATORS KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com...
  • Page 7 N / C A. LOCAL SENSING B. REMOTE SENSING FIGURE 4. LOAD CONNECTION KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818 228-1898 REV 1...
  • Page 8: Operation

    0 = output disabled) to logic 0 = output enabled, logic 1 = output disabled. 5. Do not change S2 settings. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1898 REV 1...
  • Page 9: Normal Power-Up

    The circuit breaker is “trip-free” design; if overload exists, contacts cannot be held closed by actua- tor. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818...
  • Page 10 Value (+): 0 to +I CURR:LIM:POS Onom Value (–): 0 to –I Onom KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1898 REV 1 032818...
  • Page 11: Voltage/Current Protect Limits (Limit Channel Software Limits)

    The complementary software limits are unchanged - they must be changed manually if needed. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818...
  • Page 12 KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com...
  • Page 13: Configure Load Type

    126 segments using LIST commands. • Analog Remote Operation - via Analog I/O • Operator Testing. port. KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818 228-1898 REV 1...
  • Page 14 18.235 [463.16] 18.985 [482.21] FIGURE 6. BOP 1KW OUTLINE DIMENSIONS (SHEET 1 OF 2) KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 228-1898 REV 1...
  • Page 15 SEE NOTE 6. DETAIL "A" FIGURE 6. BOP 1KW OUTLINE DIMENSIONS (SHEET 2 OF 2) KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102 http://www.kepcopower.com   email: hq@kepcopower.com 032818 228-1898 REV 1...
  • Page 16 KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A.  TEL (718) 461-7000   FAX (718) 767-1102  http://www.kepcopower.com   email: hq@kepcopower.com 228-1898 REV 1 032818...

Table of Contents