Using Segments To Build A Waveform - KEPCO BOP 1000W Operator's Manual

High power bipolar power supply
Hide thumbs Also See for BOP 1000W:
Table of Contents

Advertisement

6. When adding a new segment, the parameters of the highlighted segment are copied. It is
not possible to move or copy a segment to another location. Refer to Table 3-11, Note 2 for
details about initial vs. repeating segments. Refer to PAR. 3.3.9.9 for a detailed example of
how to add segments to build a complex waveform.
3.3.9.9

USING SEGMENTS TO BUILD A WAVEFORM

The following steps provide detailed instructions to illustrate how a complex waveform, illus-
trated in Figure 3-11, may be created by building segments. Refer to PAR. 3.2.4 for details on
changing parameters if needed.
1. After observing the precautions of PAR. 3.3.9.1, press
the Saved Waveforms screen (Figure 3-9), highlight a waveform designated Empty and
@
press
2. The initial waveform settings are displayed (see Table 3-11 and Table 3-12 for parameter
details. Use
to save the setting.
Name
Mode
Protection
Positive
Negative
Count
Segment
Type
Frequency (Hz)
Amplitude (p-p)
Offset
When all settings are complete, press
ing negative ramp starting at +10V decreasing to +6V since it is a 4V p-p signal riding on an
8V offset. The frequency of 50 Hz establishes the time duration of 20 ms for the segment.
BOP HIPWR 080709
FIGURE 3-11.
to create a new waveform.
!
to modify the initial settings for the waveform. For each parameter, use
CAP CHARG
VOLTAGE
10
10
0
Neg Ramp
50
4
8
SAMPLE WAVEFORM
@
from the power-up screen to enter
$
to save for power-up. This step creates a repeat-
$
3-31