KEPCO
®
THE POWER SUPPLIER™
Once the power supply is installed (see full Technical Manual), this guide is an aid that briefly outlines a simple approach to accomplishing
common tasks, with the appropriate Technical Manual paragraph references for more details. All instructions start from the power-up
%
screen (press
from most submenus to return to power-up screen). Many setup functions can be password protected - see UTILITY
below for instructions.
UTILITY
How do I access a password-protected menu?
presses of the keys for letters or symbols:
9
T
(TUV),
(WXYZ).
to enter next character,
How do I use the keypad?
rent mode, arrow keys highlight selections, numbers enter values and multiple presses can enter alphanumeric characters, +/– sets sign,
CLEAR sets numeric values to zero, clears alphanumerics, RESET is equivalent to power-up cycle, ENTER applies settings to output and
saves changes, HELP is context sensitive, keep pressing for more,
PAR. 3.2.1).
How do I use the ADJUST control?
If output is on, directly controls output (pressing ENTER not required). Scrolls through all alphanumeric characters for password.
How do I turn the beep on or off?
save for power-up (see PAR. 3.2.5.3).
How do I set the display background to black or white?
$
exit or
to save for power-up (see PAR. 3.2.5.1). If
How do I adjust the Display contrast?
save for power-up (see PAR. 3.2.5.1). If
How do I choose between graphical meters or time line graphs?
appropriate Graph time, then
CONTROLLING THE OUTPUT USING THE FRONT PANEL (LOCAL)
How do I apply a voltage or current to the load?
(STANDBY indicator lit). Use MODE to select Voltage or Current mode, use
then press ENTER. Highlight protect channel(s) and use keypad to set value. then press ENTER. Press STANDBY to turn output on and
apply programmed settings to load (see PAR. 3.3.3).
How do I change between a single value or two different values for positive and negative protection limit?
!
light Max/Min Settings,
, Higlight Protect Entry,
(see PAR. 3.3.3.1).
How can I prevent voltage (in voltage mode) or current (in current mode) from being set beyond a predetermined
%
level?
, highlight Max/Min Settings,
$
pad to change value, then
How do I prevent protection limit from being set beyond a predetermined level?
Higlight +C Protect Max, -C Protect Min, +V Protect Max or -V Protect Min as desired,
$
exit or
to save for power-up (see PAR. 3.3.4.2).
What happens when the protect setting is reached?
TECT (current protection in voltage mode) VPROTECT (voltage protection in current mode) or PROTECT (external analog protection).
POWER SUPPLY SETUP
How do I configure for resistive, active or battery type load?
$
%
tery then
. Press
to exit or
How do I control whether the output is on or off upon *RST?
$
%
$
. Press
to exit or
How do I control what condition the unit is in upon power up.
highlight desired power-up state, then
KEPCO, INC. $ 131-38 SANFORD AVENUE $ FLUSHING, NY. 11355 U.S.A. $ TEL (718) 461-7000 $ FAX (718) 767-1102
©2005, KEPCO, INC
Data subject to change without notice
BOP 1000W QUICK REFERENCE GUIDE
Enter first character of password using ADJUST control or keypad (use multiple
0
1
(space),
!
to verify. If incorrect, press CLEAR and repeat (see PAR. 3.2.4.4).
STANDBY sets output on/off (STANDBY indicator lit when output off), MODE selects voltage mode or cur-
Adjusts value of highlighted digit, fine adjustment (least significant digit) if held in while adjusting.
#
, highlight Key Press Beep,
$
#
#
,
, then
$
not available, see NOTE to PAR. 3.2.5).
$
%
$
.
to exit or
to save for power-up (see PAR. 3.2.5.4).
!
, highlight Bipolar or Independent, then
!
. Higlight +Voltage Max, -Voltage Min, +Current Max or -Current Min as desired,
%
$
.
to exit or
to save for power-up (see PAR. 3.3.4).
$
to save for power-up (see PAR. 3.3.6).
to save for power-up (see PAR. 3.5.3.1.3).
$
. Repeat for all parameters, then
http://www.kepcopower.com $ email: hq@kepcopower.com
2
3
(+, –, /),
(ABC),
(DEF),
!
%
through
functions are defined by graphic box to the left (see
!
, highlight On, Error only or Off, then
#
, higlight Background,
not available, see NOTE to PAR. 3.2.5).
#
when contrast is OK.
#
:
, Higlight Graphic Display,
If output is on (STANDBY indicator not lit) press STANDBY to turn output off
Y
U
or
Limit channel controls power supply, display shows the message CPRO-
%
, highlight Load Type,
%
!
,
, highlight *RST sets Output,
%
, highlight Power Up Settings,
%
to exit or
228-1530-R8A
4
5
6
(GHI),
(JKL),
(MNO).
$
!
, highlight Black or White, then
R
T
or
for fine adjustment.
!
, highlight Meters or the
to highlight main channel, use keypad to set value,
$
%
$
.
to exit or
%
, highlight Max/Min Settings,
!
, use keypad to change value, then
!
, highlight Active, Resistive, or Bat-
!
, highlight On or Off, then
!
, highlight parameter,
$
to save for power-up (see PAR. 3.3.7).
7
8
(PQRS),
%
$
.
to exit or
to
$
%
.
to
%
$
to exit or
to
%
, high-
to save for power-up
!
, use key-
!
,
$
%
.
to
!
,
8/7/09