Multiple Units Menu Functions - KEPCO BOP 1000W Operator's Manual

High power bipolar power supply
Hide thumbs Also See for BOP 1000W:
Table of Contents

Advertisement

SETTING
(BOLD = Factory Default)
CONFIGURATION
UNIT TYPE
(for parallel and series
selections only)
CONNECTION TYPE
(for parallel and series
selections only)
c. From the Multiple Units menu, highlight Configuration (use ADJUST control or the
U
or
keys) and press
3.2.4.4). Select Series, Parallel, Master 2X2 or Master 3X2 and press
the change.
d. If either Series or Parallel were selected in step c above, Connection Type shows
Series or Parallel as selected. Highlight Unit Type and press
light SLAVE #1 and press
e. Exit the Multiple Units menu and return to main screen by pressing
upon power-up. The unit goes to REMOTE mode, the status message reads MASTER
Module not found, the Fault indicator is lit, and the unit continues to beep once a min-
ute until the master is found. The only function keys displayed are
the system is running,
CAUTION: THE UNITS ARE NOW CONFIGURED AS SLAVE(S) TO BE CONTROLLED
2. Repeat step 1 as necessary to configure all slaves, but at step c highlight applicable SLAVE
# as appropriate. Each slave MUST have a different number that is sequentially
assigned.
3. Turn on the unit to be configured as a master and note that upon power up the FAULT light
will go on (this is normal). Proceed as follows:
2-20
TABLE 2-12. MULTIPLE UNITS MENU FUNCTIONS
CHOICES
STANDALONE
STANDALONE - Unit operates independently, no additional units connected.
PARALLEL
PARALLEL - Unit to be configured for parallel operation; opens UNIT TYPE
SERIES
and CONNECTION TYPE options shown below. Used when units are con-
MASTER 2 X 2
nected in parallel (increase output current) (see NOTE below).
MASTER 3 X 2
SERIES - Unit to be configured for series operation; opens UNIT TYPE and
CONNECTION TYPE options shown below. Used when units are connected
in series (increase output voltage) (see NOTE below).
MASTER 2 X 2 - Unit configured as master in control of two parallel branches
comprised of two series connected units. Used when units are connected in
parallel and series to double output voltage and current (see NOTE below).
MASTER 3 X 2 - Unit configured as master in control of two parallel branches
comprised of three series connected units. Used when units are connected in
parallel and series to triple output voltage and double output current (see
NOTE below).
STANDALONE
STANDALONE - Unit operates independently, no additional units connected.
MASTER +1
MASTER+1 - Unit is the master (controller), with one slave unit connected.
MASTER +2
MASTER+2 - Unit is the master (controller), with two slave units connected.
MASTER +3
MASTER+3 - Unit is the master (controller), with three slave units connected.
MASTER +4
MASTER+4 - Unit is the master (controller), with four slave unit connected.
SLAVE #1
SLAVE #1 - Unit is slave no. 1 in configuration using one to five slave units.
SLAVE #2
SLAVE #2 - Unit is slave no. 2 in configuration using two to five slave units.
SLAVE #3
SLAVE #3 - Unit is slave no. 3 in configuration using three to five slave units.
SLAVE #4
For Master 2X2 and Master 3X2, slave #3 is always the unit controlled in par-
SLAVE #5
allel by the master.
SLAVE #4 - Unit is slave no. 4 in configuration using four or five slave units.
SLAVE #5 - Unit is slave no. 5 in MASTER 3X2 configuration using two paral-
lel branches comprised of three series-connected units.
PARALLEL
Not Selectable - Indicates whether parallel or series was chosen as Configu-
SERIES
ration type.
!
to modify. When prompted, enter ADMIN2 password (see PAR.
$
to apply the change.
!
and
ONLY BY THE MASTER. DO NOT USE THE SLAVE KEYPAD, RS 232 PORT
OR GPIB PORT TO TRY TO CONTROL THE SLAVE(S).
%
are no longer available;
FUNCTION
!
to modify. High-
$
to save the settings
!
#
,
and
#
functions normally.