KEPCO BOP 1000W Operator's Manual page 24

High power bipolar power supply
Hide thumbs Also See for BOP 1000W:
Table of Contents

Advertisement

SPECIFICATION
PROGRAMMING/DISPLAY CHARACTERISTICS
Analog I/O Port
(See Table 2-10)
(voltage or current)
(±Voltage, ±Current)
External Protection Port
External Shutdown
(see Table 2-4)
External Shutdown
Trigger Port
(See Table 2-3)
Digital control
Display
FUNCTION GENERATOR CHARACTERISTICS
Maximum number of waveforms
Maximum number of segments or basic wave-
forms per waveform
1-4
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
RATING/DESCRIPTION
Main channel
Protection Limit
channels:
Mode Control
Voltage: open circuit or TTL logic 1
Current: short circuit or TTL logic 0
Output Current
0 to ±10 Volts corresponds to zero to
Analog Readback
± Full Scale nominal output current
Isolated input for shutdown of the
BOP (latched status)
Isolated output indicating
Flag
External On-Off
Isolated output indicating
Flag
output on (enabled, STANDBY off) or
off (disabled, STANDBY on) status)
External Trigger
Isolated input for setting the BOP
Shutdown
in STANDBY (output off)
External Trigger
Isolated input for trigger events
Input
local
Panel-mounted keypad
remote
IEEE 488-2 (GPIB)
remote
remote
front panel
remote
–10V to +10V
+1V to +10V
shutdown status)
(latched status)
RS 232
RS 485 (BITBUS)
4" backlit LCD displays all functions
All parameters read back on GPIB or RS 232 buses
(See PAR. 3.3.9)
Local: 16
Remote: 1
Local: 10
Remote: 126
RATING/DESCRIPTION
Full range output, 20K Ohm input impedance
(see PAR. 3.4)
10% to 100% of Nominal Range. Input voltage
clamped to 12V through 1K ohms. Maximum
of 0.15mA input current at1V input voltage.
Available only when digitally activated through
Power-up setting..
Output impedance of this signal is 2K Ohms.
Pulse width: 100 microseconds min.
Action delay: 100 microseconds max
Restore operation by cycling input power or
pressing RESET key.
Action delay: 100 microseconds max
Action delay: 200 milliseconds max
Pulse width: 100 microseconds min.
Action delay: 200 milliseconds max
Restore operation by pressing STANDBY key.
or sending OUTP ON command via remote
interface.
Pulse width: 100 microseconds min.
Action delay: 500 microseconds max
Direct Entry
SCPI
IEEE 1118
Local: Saved for power-up
Remote: Lost when the unit is turned off, must
be saved on the host computer)
Or maximum number of points (whichever
comes first)
• The time interval for each segment
depends on the type of waveform: period
for ramp and square waveforms, period or
fraction of period for sine and triangular
waveforms and time interval for DC levels
• Segments that cause the waveform to
exceed the maximum number of points are
not executed. For local operation they are
marked with a triple asterisk on the front
panel. For remote operation an error mes-
sage is generated.
BOP HIPWR 080709