SPECIFICATION
FUNCTION GENERATOR CHARACTERISTICS (Continued)
Types of Basic waveforms
Maximum number of points per basic wave-
form
Count (Number of repetitions)
Waveform Name
Waveform Parameters
Basic waveform parameters
BOP HIPWR 080709
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
RATING/DESCRIPTION
Sine (Sinusoidal waveform)
Triangle (Triangular waveform)
Pos. Ramp (Ramp waveform)
Neg. Ramp (Sawtooth waveform)
Square (50% Duty Cycle Pulse)
Level (DC waveform)
Local: 3933
Range: 1 to 255
For Count = 0 the waveform is exe-
cuted indefinitely until stop com-
mand is sent
10 characters maximum
Type: Voltage or Current
Positive Protection Limit:
(Vd-c or Ad-c)
Negative Protection Limit:
(Vd-c or Ad-c)
Count: number
Initial/Repeating
Sine: Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c),
Start Phase (°), Stop Phase (°).
Triangular: Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c), Start
Phase (°), Stop Phase (°).
Ramp (Pos. or Neg.): Frequency (Hz), Amplitude (Vp-p or Ap-p),
Offset (Vd-c or Ad-c).
Square: Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c).
Level: Timing (sec), Amplitude (Vd-c or Ad-c).
• Local: the Start/Stop phases, available for sine and triangle only, can be set or
edited by modifying the existing segment (see PAR. 3.3.9.7).
• Remote: the start/stop phases are global parameters, applicable to all sine/ trian-
gular waveform segments.
• The Start/Stop points are independent and can have any value between 0° and
360°.
RATING/DESCRIPTION
• Local: When the count is complete or if
execution is stopped using
of the unit is set to OFF (Standby indicator
lit). Output must be enabled (press
STANDBY) to execute the waveform
again.
• Remote: When the count is complete or
the waveform is stopped using
VOLT:MODE FIX command, the output
remains at last output value.
• Type of waveform, voltage or current, can
be selected only for a new waveform and
consequently applies to all waveform seg-
ments. Changing the type for an existing
waveform is not possible, unless the wave-
form is erased first.
• The Limit values (positive/negative) and
the count number apply to all waveform
segments and can be edited at the begin-
ning of a new waveform or later when mod-
ifying a waveform (see PAR. 3.3.9.7).
• All segments except the last may be set to
run once (Initial) or per the Count setting
(Repeating).
%
, the output
the
1-5