1. With POWER switch set to off position, connect the power supply to source power (see PAR.
2.5.2).
2. With no load connected, set POWER switch to the ON position. Each time the unit is turned
on an internal self-test is performed. The alphanumeric display (LCD) shows the processor
firmware revision history and lists various tests performed during the internal self-test. As
each test is completed, PASS or FAIL is displayed. If all tests pass, the unit goes into the
default mode. If a failure occurs, the failure is displayed. Figure 3-3 shows the factory config-
ured power on defaults displayed on the LCD.
TABLE 2-11. IEEE 488 PORT INPUT/OUTPUT PIN ASSIGNMENTS
CONNECTOR
IEEE 488
PORT
J5
3. Connect a digital voltmeter (DVM) (resolution and accuracy of 0.01% or better) to the
OUTPS and COMS terminals at the rear panel terminal block.
4. Use the keypad to enter the rated maximum voltage of the power supply (e.g., enter 36 for a
model BOP 36-28MG) and press ENTER. If STANDBY indicator is lit, press STANDBY key.
5. Verify DVM voltage reading agrees with programmed voltage within 0.03% of rated maxi-
mum voltage and agrees with displayed voltage on LCD within 0.05% of rated maximum
voltage.
BOP HIPWR 080709
PIN
SIGNAL NAME
I
1
D
01
I
2
D
02
I
3
D
03
I
4
D
04
5
EOI
6
DAV
7
NRFD
8
NDAC
9
IFC
10
SRQ
11
ATN
12
SHIELD
I
13
D
05
I
14
D
06
I
15
D
07
I
16
D
08
17
REN
18
GND
19
GND
20
GND
21
GND
22
GND
23
GND
24
LOGIC GND
FUNCTION
I/O Line
I/O Line
I/O Line
I/O Line
End or Identify
Data Valid
Not Ready for Data
Not Data Accepted
Interface Clear
Service Request
Attention
Shield
I/O Line
I/O Line
I/O Line
I/O Line
Remote Enable
Ground (signal common)
Ground (signal common)
Ground (signal common)
Ground (signal common)
Ground (signal common)
Ground (signal common)
Logic Ground
2-7