SETTING
(BOLD = Factory Default)
+V Protect Max
Eomax +1% of Eomax
+V Protect Min
(internal value)
Not Adjustable
–V Protect Max
(internal value)
Not Adjustable
–V Protect Min
Eomax + 1% of Eomax
NOTE: To restore all Max/Min settings defaults, press
@
press
to restore defaults shown above in BOLD. Press
saving for power-up) and exit.
3.3.4.1
CHANGING MAXIMUM ACCEPTED VOLTAGE OR CURRENT (MAIN CHANNEL SOFT-
WARE LIMITS)
The software limits for the main channels (+Voltage Max, –Voltage Min, +Current Max and –
Current Min) are the maximum (positive) and minimum (Maximum negative) values allowable
for voltage and current. The default software limits are determined by the model: the nominal
(rated) values for voltage and current (e.g., 36V and 28A for the BOP 36-28MG). These four
values can be adjusted independently. For example, a BOP 36-28MG, capable of delivering
±36V in voltage mode can be configured to allow voltage to be adjusted only from –1V to
+15V by setting –Voltage Min to –1 and +Voltage Max to +15. Similarly, a BOP 36-28MG,
capable of delivering ±28A in current mode can be configured to allow current to be adjusted
from –0.5A to +10A by setting –Current Min to –0.5 and +Voltage Max to +10. Adjustment
range is between 0 and E
ware limits are not the same as the Protect Limits described in PAR. 3.3.4.2.
The main channel software limit values can be lowered (closer to zero) by the user, e.g., to pre-
vent inadvertent damage to a specific circuit under test. When the maximum/minimum values
are lowered, the unit will not accept values that exceed the new software limits. If the user
attempts to enter a value that exceeds the software limit, the unit will continue to function. in
local mode the Exceeding Maximum Allowed Value message is displayed, and the output
will be clamped to the main channel software limit (maximum/minimum) value. In remote mode
the command is considered invalid and is disregarded: a 120 error is produced and the mes-
sage Voltage Out of Range or Current Out of Range is displayed on the front panel.
The main channel software limits are always in effect, even when the unit is controlled by an
external reference. If main channel software limits are changed from the default, the pro-
tection limits must be changed to correspond to the new software limits (see PAR.
3.3.4.2). As an example, changing +Voltage Max and –Voltage Min of a BOP 36-28MG to ±3V,
respectively, causes the unit to behave as if it was a BOP 3-28MG. In this case it is important to
change the +V Protect Max and –V Protect Min limits (e.g., to ±3.3V, respectively) so that the
load is protected when operating in Current Mode.
%
1. Press
Max/Min Settings.
!
2. Press
is required, see PAR. 3.2.4.4 for instructions.)
BOP HIPWR 080709
TABLE 3-5. MAX/MIN SETTINGS MENU (CONTINUED)
CHOICES
(value)
Defines the maximum value that +Voltage Protect can be set to. To modify refer
to 3.3.4.1.
Defines the minimum value that +Voltage Protect can be set to. This is a calcu-
lated value and is not adjustable from the front panel.
Defines the maximum (minimum negative) value that –Voltage Protect can be
set to. This is a calculated value and is not adjustable from the front panel.
(value)
Defines the minimum (maximum negative) value for –Voltage Protect. To modify
refer to 3.3.4.1.
%
for voltage and 0 and I
Onom
from the power-up screen to enter the General Setup menu, then highlight
to enter the Max/Min Settings submenu (Figure 3-7 and Table 3-5). (If a Password
FUNCTION
from the power-up screen, highlight Max/Min settings, press
$
to save for power-up or
Onom
%
to apply the changes (without
for current. Note that these soft-
!
, then
3-17