3.3.3.1

SELECTING BIPOLAR/INDEPENDENT PROTECTION LIMITS

The BOP can be configured to show the protection limits as either a single value that applies to
both protection channels or show individual settings for positive and negative protection limits.
Selecting Independent protection limits means that the positive and negative limits are dis-
played (and can be modified) independently. Bipolar means that for each protection limit (volt-
age or current) a single value applies to both the positive and negative limits; only one value is
displayed and can be edited for both ± protection limits.
TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS
Term
+E
The nominal (rated) output voltage of the unit determined by model; e.g. for
Onom
–E
a BOP 36-28MG, ±E
Onom
+I
The nominal (rated) output current of the unit determined by model; e.g. for
Onom
–I
a BOP 36-28MG, ±I
Onom
+Voltage
Voltage mode only. Positive (+) and negative (–) output voltage values
–Voltage
established by keypad or remote command.
Range (+): 0 to +Voltage max
Range (–): 0 to –Voltage min
+Voltage max
Voltage mode only. Maximum (positive) and minimum (maximum negative)
–Voltage min
voltage that can be set.
Value (+): 0 to +E
Value (–): 0 to –E
+Current Protect
Voltage mode only. Defines maximum (+) current and Minimum (maximum
–Current Protect
negative) (–) that unit can source or sink.
Range (+): +Current Protect min to +Current Protect max
Range (–): –Current Protect max to –Current Protect min
+Current Protect Max
Voltage mode only. Maximum setting for +Current Protect and Minimum
–Current Protect Min
(maximum negative) setting for –Current Protect.
Value (+): +Current Protect min to (1.01 x +Current max)
Value (–): –Current Protect max to (1.01 x –Current min)
Minimum (box)
Voltage mode only. Minimum (positive) setting for +Current Protect and
+Current Protect Min
maximum (maximum negative) setting for –Current Protect. Values of ±Cur-
–Current Protect Max
rent Protect between +Current Protect Min and –Current Protect Max (near
zero) are not allowed.This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-3).
+Voltage Protect
Current mode only. Maximum positive (+) and minimum (maximum
–Voltage Protect
negative) (–) voltage that can appear at the output.
Range (+): +Voltage Protect min to +Voltage Protect max
Range (–): –Voltage Protect max to –Voltage Protect min
+Voltage Protect Max
Current mode only. Maximum (positive) setting for +Voltage Protect and
–Voltage Protect Min
Minimum (maximum negative) setting for –Voltage Protect.
Value (+): +Voltage Protect min to (1.01 x +Voltage max)
Value (–): –Voltage Protect max to (1.01 x –Voltage min)
BOP HIPWR 080709
Definition
is 36V.
Onom
is 28A.
Onom
Onom
Onom
To modify
refer to PAR.
Local
Remote
N/A
N/A
N/A
N/A
3.3.3
B.84
3.3.4.1
B.86, B.87,
B.88, B.90
3.3.3
B.27, B.28,
B.33, B.31
3.3.4.2
B.35, B.36,
B.39, B.37
N/A
N/A
3.3.3
B.94, B.95,
B.100,
B.98
3.3.4.2
B.102,
B.103,
B.106,
B.104
3-13

Advertisement

Table of Contents
loading

Table of Contents