KEPCO BOP 1000W Operator's Manual page 130

High power bipolar power supply
Hide thumbs Also See for BOP 1000W:
Table of Contents

Advertisement

Type
Step
Remote Calibr.
1. ZERO
VOLTAGE
2. POSITIVE
EXTERNAL
PROTECTION,
Pos. Voltage
Neg. Voltage
(together)
CURRENT,
1. ZERO
INTERNAL
2. POSITIVE
3. NEGATIVE
CURRENT,
1. POSITIVE
PROTECTION
2. NEGATIVE
CURRENT,
1. ZERO
EXTERNAL
2. POSITIVE
CURRENT,
1. ZERO
GAIN
2. POSITIVE
EXTERNAL
1. ZERO
CONTROLS,
2. POSITIVE
PARALLEL
EXTERNAL
1. ZERO
CONTROLS,
2. POSITIVE
I_OUT
Remote Calibr.
1. ZERO
CURRENT
2. POSITIVE
EXTERNAL
PROTECTION,
Pos. Current
Neg. Current
(together)
4-2
TABLE 4-1. CALIBRATION SUMMARY (CONTINUED)
Reference Type
and Value
External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pin 14+6 ref to
pin12)
Internal
Internal
External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pin 11 ref to 4)
External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pin 11 ref to 4)
External:
1. 0.0V
2. +10.0V
(Par/Ser CTRL-IN
Port pin3 ref. to
pin1)
INTERNAL
External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pins 13, 5 ref to
pin 12)
Monitored
Output Conditions
Parameter
N/A
No requirements
Output Current:
Short with Meas.
1. 0.0A
Shunt
2. +Current FS
Automatic CM
3. –Current FS
Output Current:
Short with Meas.
1. +Current FS
Shunt
2. -Current FS
Automatic VM
Output Current:
Short with Meas.
1. 0.0A
Shunt
2. +Current FS
Automatic CM
Output Current:
Short with Meas.
1. 0.0A
Shunt
2. 0.0A
Automatic CM
Output Current:
Short with Meas.
1. 0.0A
Shunt
2. +Current FS
Automatic CM
Voltage at Par/Ser
Short with Meas.
CTRL-IN Port pin 6
Shunt
ref. to pin1:
Automatic CM
1. 0.0V
2. +10.0V
N/A
No requirements
Notes
1. Automatic internal
measurement
2. Remote Calibration
only.
1. DVM between probe
terminals of Meas.
Shunt (LO towards
COM S)
2. Adjust for zero, posi-
tive and negative FS
1. DVM between probe
terminals of Meas.
Shunt (LO towards
COM S)
2. Adjust for positive
and negative FS.
1. DVM between probe
terminals of Meas.
Shunt (LO towards
COM S).
2)Adjust for zero, pos
FS.
1. DVM between probe
terminals of Meas.
Shunt (LO towards
COM S)
2. Adjust for zero
(both Zero and Positive)
1. DVM between probe
terminals of Meas.
Shunt (LO towards
COM S)
2. Adjust for zero, pos.
FS
3. Calibrate unit for
Slave in Parallel
1. DVM at Par/Ser
CTRL-IN Port pin 6 ref.
to pin 1
2. Adjust for zero,
+10.0V
3. Calibrate unit for
Master in Parallel
1. Automatic internal
measurement
2. Remote Calibration.
only.
BOP-1K 080709